Spec Sheet

Garland Commercial Ranges Ltd.
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
General Inquires 1-905-624-0260
USA Sales, Parts and Service 1-800-424-2411
Canadian Sales 1-888-442-7526
Canada or USA Parts/Service 1-800-427-6668
Form# MCOGS1020ESS (04/14/15)
Master Gas Convection Oven
SINGLE-DECK
MODELS
INT. DIMENSIONS: In mm EXT. DIMENSIONS: In mm SHIP WT. SHIP DIM.
W H D W H D lbs/kg cubic Ft.
Standard Depth 29 (736) 24 (610) 24 (610) 38 (965) 57-1/2 (1461) 41-1/4(1048) 515/230 64
DOUBLE-DECK
MODELS
INT. DIMENSIONS: In mm EXT. DIMENSIONS In mm SHIP WT. SHIP DIM.
W H D W H * D 2@lbs/kg Cubic Ft.
Standard Depth 29 (736) 24 (610) 24 (610) 38 (965) 70 -1/2 (1791) 41-1/4(1048) 1030/465 128
*Height with or without standard casters. Height with low prole casters (double deck) is 68-1/2" (1740mm).
MODELS
INPUT RATINGS, NAT ELECTRICAL SPECIFICATIONS
BTU/hr kW Eqiv. Gas inlet 120V/1Ph. 240V/1Ph.
Single Deck 60,000 17.6 (1)@3/4” NPT (1)@9.8A (1)@5.2A
Double Deck 120,000 35.2 (1)@1” NPT (2)@9.8A (2)@5.2A
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60Hz.
3. (240V units) 200-240V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60 Hz
4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug.
5. Garland recommends a separate 15 AMP circuit for each 120V unit.
6. Gas Input Ratings shown above are for installations up to 2,000 ft. (610m) above sea level.
Specify altitudes over 2,000 ft.
Installation Notes:
Combustible Wall Clearances:
*Sides: 1" (25mm)
Back: 3" (76mm)
*Note: Installations beside units with
high heat sources it is recommended
to leave 6" (152mm) on the right side of
oven. Refer to the installation manual for
more detail
Entry Clearance:
Crated: 47" (1194m m)
Uncrated: 32½" (826mm)
Manifold Operating Pressure:
Natural: 4.1" WC
Note: Data applies only to North America