Manual
Dimensions and Technical Specifications RTCSmp Built-In Temperature Controlled Hold-Line
Part # 4532286 Rev 3 (6/10/14) 7
3 Dimensions and Technical Specifications
3.1 Rating Plate
T
he rating plate specifies important information such as model number,
serial number, and electrical specifications. The rating plate is affixed to
the bottom of the generator, by the connectors at the front.
3.2 Nomenclature and Models
Series Built-In Power (Watt) Model
HO = Hold Line IN
450 (1 heat-retaining plate) HO IN 450
900 (2 heat-retaining plates) HO IN 900
1350 (3 heat-retaining plates) HO IN 1350
1800 (4 heat-retaining plates) HO IN 1800
3.3 Dimensions
Component Dimensions (width x length x height)
Generator Housing 11.93”x 12.28”x 5.31” (303 x 312 x 135mm)
Heat-Retaining Plate 12.68”x 12.68”x 2.95” (322 x 322 x 75 mm)
Ceran Glass 12.68”x 12.68”x 0.16” (322 x 322 x 4 mm)
3.4 Electrical Specifications
Model Voltage Power
Power Per Heating Plate
HOIN450/900/1350/1800 120 V AC / 1Ph 1800 W / 16A 450W
HOIN450/900/1350/1800 230 V AC / 1Ph 1800 W / 8A 450W
3.5 Operating Conditions
Max.
T
olerance of Nominal Supply Voltage +6 /-10 %
Supply frequency 50/60 Hz
Ingress Protection class IP X0
Minimal Diameter of Induction Pan 5” (12cm)
Maximum Ambient
T
emperature In Storage > -4°F to +158°F (-20°C to +70°C)
In Operation >+ 41°F to +104°F (+5°C to +40°C)
Maximum Relative Air Humidity In Storage > 10% to 90%
In Operation > 30% to 90%
Set Temperature Range 122-212°F
/
50-100°C
Maximum air flow: 56.50cfm / 96m
3
per hour and min. opening: 9.30 sq.in. / 6000mm
2
is required.
3.6 Compliances
North American models:
ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001
CE models comply with the latest European Norms:
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)