Manual
Dimensions and Technical Specifications    RTCSmp Built-In Temperature Controlled Hold-Line 
Part # 4532286 Rev 3 (6/10/14)    7 
3  Dimensions and Technical Specifications 
3.1  Rating Plate  
T
he rating plate specifies important information such as model number, 
serial number, and electrical specifications. The rating plate is affixed to 
the bottom of the generator, by the connectors at the front. 
3.2   Nomenclature and Models 
Series  Built-In  Power (Watt) Model
HO = Hold Line IN 
450 (1 heat-retaining plate) HO IN 450
900 (2 heat-retaining plates) HO IN 900
1350 (3 heat-retaining plates) HO IN 1350
1800 (4 heat-retaining plates) HO IN 1800
3.3  Dimensions 
Component  Dimensions (width x length x height) 
Generator Housing  11.93”x 12.28”x 5.31” (303 x 312 x 135mm) 
Heat-Retaining Plate  12.68”x 12.68”x 2.95” (322 x 322 x 75 mm) 
Ceran Glass  12.68”x 12.68”x 0.16” (322 x 322 x 4 mm) 
3.4  Electrical Specifications 
Model  Voltage  Power 
Power Per Heating Plate 
HOIN450/900/1350/1800  120 V AC / 1Ph  1800 W / 16A 450W 
HOIN450/900/1350/1800  230 V AC / 1Ph  1800 W / 8A 450W 
3.5  Operating Conditions 
Max. 
T
olerance of Nominal Supply Voltage +6 /-10 %
Supply frequency  50/60 Hz
Ingress Protection class  IP X0
Minimal Diameter of Induction Pan 5” (12cm)
Maximum Ambient 
T
emperature  In Storage > -4°F to +158°F (-20°C to +70°C)
In Operation >+ 41°F to +104°F (+5°C to +40°C)
Maximum Relative Air Humidity  In Storage > 10% to 90%
In Operation > 30% to 90%
Set Temperature Range  122-212°F
/
 50-100°C
Maximum air flow: 56.50cfm / 96m
3
per hour and min. opening: 9.30 sq.in. / 6000mm
2
 is required.
3.6  Compliances 
  North American models: 
ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001 
  CE models comply with the latest European Norms: 
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV) 










