10.3  Troubleshooting with Error Codes (for Service Technicians) 
To obtain the internal data for troubleshooting, you need an IR Adapter, proper connectors, and software. The 
table below is a reference guide. For further information and assistance, please contact Garland Technical Service. 
Error 
Code 
Reason  Things To Check 
E01  Hardware overcurrent or coil is not connected(1) Check the Chafing Dish or Pan material, Check
wiring. 
E02  Software overcurrent (1)  Check the Chafing Dish or Pan material.
E03  Heat sink overtemperature 
T > 85°C (1) 
Check installation (Airflow). 
E04  Empty cooking detektor 
Total failure of the sensor unit or sensor unit not 
connected (1) 
Check sensor unit.
Set point: 1080Ohm at 25°C 
E05  Potentiometer defect or not connected (1) Check the potentiometer wiring. 
E06 
T
emperature inside the generator too high.
T
 > 
80°C (1) 
Check installation (Airflow). 
E10  Reduction KK temperature 
T > 75°C (2) 
Check installation (Airflow). 
E12  Reduction internal temperature
T > 70°C (2) 
Check installation (Airflow). 
E20  Faulty or not connected heat sink temperature 
sensor (1) 
Contact Garland.
E21  Board sensor defect (1)  Contact Garland.
E24 
T
emperature processor central unit > 100°C (1) Check installation (Airflow). 
E30  Heat retention plate sensor 1 over temperature 
or defect (1) 
Check warming process. Check sensor 1 Set point: 
1080Ohm at 25°C 
E41  Heat retention plate sensor 2 over temperature 
or defect (1) 
Check warming process. Check sensor 2 Set point: 
1080Ohm at 25°C 
E42  Heat retention plate sensor 3 over temperature 
or defect (1) 
Check warming process. Check sensor 3 Set point: 
1080Ohm at 25°C 
E43  Reduction KK temperature 
T > 75°C (2) 
Check installation (Airflow). 
(1) Power supply is interrupted immediately. 
(2) The unit works with reduced power. 