4.4  Heat Retaining Plate Installation 
4.4.1  Dimensions: RTCSmp HOIN1500 Induction Heat Retaining Plate 
(measurements in mm and [inch]) 
4.4.2  Cut-Out Dimensions and Clearance 
The RTCSmp HO/IN unit is to be flush-mounted. A support frame or support structure has to be custom 
designed and built for housing the unit. 
A.  Cut-out dimension on the counter surface: 
408 x 808mm [16.06” x 31.81”] 
NOTE: Dimensions include widths for silicone 
joints on all four (4) sides. Consider adjusting cut-
out dimensions based on mounting methods, see 
4.4.3 Parallel Installation. 
B.  Recommended recess depth: 8mm [0.32”] 
C.  Body clearance (height x depth x width):  
6.30” x 14.96” x 30.71” / 160 x 380 x 780mm 
800 [31.50]
800 [31.50]
772 [30.39]
400 [15.75]
372 [14.65]
400 [15.75]
114 [4.49]
14
[0.55]
7.5 [0.30]
52
[2.05]
65
[2.56]
152 [5.98] 57 [2.24]
110 [4.33]
200 [7.87]
90 [3.54]100 [3.94]
100 [3.94]
200 [7.87]
counter
surface
A
B
C