MSDS
MATERIAL SAFETY DATA SHEET
Date Issued: 10/17/08 Page 1 of 2
SECTION I – COMPANY AND PRODUCT IDENTIFICATION
MANUFACTURER’S NAME
GARDNER-GIBSON CORPORATION
STREET ADDRESS
4161 E. 7TH AVENUE
CITY, STATE, AND ZIP CODE
TAMPA, FL 33605
EMERGENCY TELEPHONE NUMBER
1-800-424-9300 CHEMTREC in the USA
PRODUCT INFORMATION
813-248-2101
PRODUCT CLASS
Acrylic Latex Sealant
MANUFACTURER’S CODE IDENTIFICATION
Product #0339-GA
Product #0338-GA
TRADE NAME
Leak Stopper Clear
SECTION II – HAZARDOUS INGREDIENTS
INGREDIENT
PERCENT
By Weight
TLV
PPM
PEL - TWA
PPM
2,2,4-Trimethyl-1,3-pentanediol Monoisobutyrate
CAS # 25265-77-4
< 2.0%
N.E.
N.E.
2-Amino-2-methyl-1-propanol
CAS # 124-68-5
< 2.0%
N.E.
N.E.
N.E. = Not Established
SECTION III – PHYSICAL DATA
BOILING RANGE: 212°F - 215°F
VAPOR DENSITY: HEAVIER THAN AIR
VAPOR PRESSURE: 25 mm Hg @ 68°F
EVAPORATION RATE:
SLOWER, THAN ETHER
PERCENT VOLATILE BY
VOLUME: 35 - 45 %
WEIGHT PER GALLON:
8.8 Lbs.
SOLUBILITY IN WATER: Dispersible PHYSICAL STATE: Paste pH 8.5
SECTION IV – FIRE AND EXPLOSION HAZARD DATA
FLASH POINT: WATER BASED – Not Applicable
Explosion Hazard: Not Applicable
LEL – Not Applicable
EXTINGUISHING MEDIA - Carbon dioxide, dry chemical, foam, or water spray
UNUSUAL FIRE AND EXPLOSION HAZARDS – None
SPECIAL FIRE FIGHTING PROCEDURES - Water can be used to cool fire-exposed containers. Self-
contained breathing apparatus and protective clothing should be worn in fighting large fires involving
chemicals
SECTION V – REACTIVITY DATA
STABILITY: STABLE
CONDITIONS TO AVOID: Store away from strong oxidizing materials.
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: Store in a cool, dry place. Keep container closed
when not in use. Protect from freezing.
HAZARDOUS DECOMPOSITION PRODUCTS: Carbon oxides and traces of incompletely burned carbon
compounds.
HAZARDOUS POLYMERIZATION: WILL NOT OCCUR