SDS

Section 6 - Accidental Release Measures
Personal Precautions, Protective Equipment And Emergency Procedures
Avoid Breathing Vapors. Ventilate Area. Remove All Sources Of Ignition.
Methods And Materials For Containment And Cleaning Up
Clean Up With Absorbent Material And Place In Closed Containers For Disposal.
Section 7 - Handling And Storage
Precautions For Safe Handling
Do Not Puncture Or Incinerate (Burn) Cans. Do Not Stick Pins,
Nails, Or Any Other Sharp Objects Into Opening On Top Of Can. Do
Not Spray In Eyes. Do Not Take Internally. See Product Label For
Additional Information.
Conditions For Safe Storage,
Including Any Incompatibilities
Store And Use In Cool, Dry, Well-Ventilated Areas. Do Not Store
Above 120 F.
Section 8 - Exposure Controls/Personal Protection
Control Parameters
Chemical Name / CAS No
Osha Exposure Limits
Acgih Exposure Limits
Naphtha (Petroleum), Hydrotreated Light
64742-49-0
TWA: 500 Ppm;
PEL-Ceiling: Not Determined
TLV-TWA: 400 Ppm
TLV-STEL: 500 Ppm
N-Hexane
110-54-3
PEL-TWA: 500 Ppm
PEL-Ceiling: Not Determined
TLV-TWA: 50 Ppm;
TLV-STEL: Not Determined
Difluoroethane
75-37-6
Not Established
TWA: 1000 Ppm
Appropriate Engineering Controls
Ventilation Should Be Sufficient To Prevent Inhalation Of Any
Vapors. General Dilution And/or Local Exhaust Ventilation In
Volume To Keep PEL/TLV Of Most Hazardous Ingredient Below
Acceptable Limit And LEL Below Stated Limit.
Individual Protection
Eye/Face
Protection
None Under Normal Use. However, Use Of Safety Glasses With Splash Guards Or
Full Face Shield Should Be Used If Indicated.
Hand
Protection
None Under Normal Use. Use Solvent-Resistant For Prolonged Or Repeated
Contact.
Other Skin
Protection
None Under Normal Use. However, Use Of Solvent- Resistant Aprons Or Other
Clothing Is Recommended. Eye Washes And Safety Showers In The Workplace Are
Recommended.
Respiratory
Protection
None Under Normal Use. Avoid Breathing Vapors. In Restricted Areas, Use
Approved Chemical/Mechanical Filters Designed To Remove A Combination Or
Particles And Vapor. In Confined Areas, Use An Approved Air Line Respirator Or
Hood. Self-Contained Breathing Apparatus Is Required For Vapor Concentrations
Above PEL/TLV Limits.