Instruction Manual

10. To bend more conduit of the same material and at the
same angle, load and secure as described in steps 3
through 6. To bend the same type conduit but at a different
angle, load and secure; turn angle set knob to the desired
angle, then press the bend button.
11. Bending different type and size conduit requires repeating
steps 2 through 10.
4.3 Offset Bending
1. Obtain distance “M” from table A, and measure this
distance from mark #1 and place mark #2.
2. Now place mark #1 in line with front edge of shoe clamp
and make first bend.
3. Next rotate conduit 180° level, place mark #2 in line with
front edge of shoe clamp and make second bend.
NOTE: When bending rigid aluminum, set bend angle indicator
approximately 4° short of desired angle, since aluminum does
not have spring-back of steel.
4.4 Stub-up Bending
1. Table C shows minimum length (inches).
2. Mark #1 is stub length, deduct from this as per table C
and obtain mark #2.
Offset
Beam
Box
M
Front Edge of Clamp
See Table A
Min. 2"
Mark #2Mark #1
5
Offset Conduit Conduit Conduit
Required Max. Size M Max. Size M Max. Size M
2"
3
4"7
3
4"
4" 1
1
2"15
7
16"
3
4"8"
6" 2" 23
3
16" 1" 12"
1
2"8
1
2"
8" 30
5
8"1
1
2" 16" 1" 11
5
16"
10" 38
5
8" 2" 20" 1
1
4"14
1
8"
12" 46
3
8" 24" 1
1
2"16
15
16"
14" 54
1
16" 28" 2" 19
13
16"
16" 61
13
16" 32" 22
5
8"
18" 67
7
16" 36" 25
7
16"
20" 77
1
4" 40" 28
1
4"
22" 85" 44" 31
1
8"
To locate distance between centers of offset bending marks other than listed in
table A use the following multipliers:
15° bend - 3.9
30° bend - 2.0
45° bend - 1.4
Table A
15° Bend 30° Bend 45° Bend
Shoe
Min. 2"
Stub Length
Set Back
Mark #2
Mark #1
Front Edge of 
Clamp Mark #2
Stub to Bottom 
of Pipe
Conduit Radius Radius
Size Rigid / IMC EMT
1
2"3
31
32"3
7
8"
3
4"4
25
32"4
29
32"
1" 5
9
16"5
29
32"
1
1
4"6
7
8"7
3
32"
1
1
2"7
9
16"7
1
2"
2" 8
9
32"8
9
16"
Table B
BEND RADIUS
1
2" Rigid 7
3
4"1
1
4" Rigid 12
3
4"
1
2" IMC 7
3
4"1
1
4" IMC 12
1
2"
1
2" EMT 7
5
8"1
1
4" EMT 13"
3
4" Rigid 9" 1
1
2" Rigid 13
1
2"
3
4" IMC 9" 1
1
2" IMC 13
1
2"
3
4" EMT 8
1
2"1
1
2" EMT 13
1
2"
1" Rigid 10
1
8" 2" Rigid 15
3
4"
1" IMC 10
1
8" 2" IMC 15
1
2"
1" EMT 10
3
8" 2" EMT 15
1
2"
Table C
Conduit Stub-up Conduit Stub-up
Size Set-back Size Set-back