10. To bend more conduit of the same material and at the
same angle, load and secure as described in steps 3
through 6.To bend the same type conduit but at a different
angle, load and secure; turn angle indicator to the desired
angle, then press toggle to bend.
11. Bending different type and size conduit requires repeating
steps 2 through 10.
4.3 Offset Bending
1. Obtain distance “M" from table A, and measure this
distance from mark #1 and place mark #2.
2. Now place mark #1 in line with front edge of shoe clamp
and make first bend.
3. Next rotate conduit 180° level, place mark #2 in
line with front edge of shoe clamp and make
second bend.
NOTE: When bending rigid aluminum, set bend angle indicator
approximately 4° short of desired angle, since aluminum does
not have spring-back of steel.
4.4 Stub-up Bending
1. Table C shows minimum length (inches).
2. Mark #1 is stub length, deduct from this as per table C
and obtain mark #2.
Offset
Beam
Box
M
Front Edge of Clamp
See Table A
Min. 2"
Mark #2Mark #1
5
Offset Conduit Conduit Conduit
Required Max. Size M Max. Size M Max. Size M
2”
3
⁄
4
”7
3
⁄
4
”
4” 1
1
⁄
2
”15
7
⁄
16
”
3
⁄
4
”8”
6” 2” 23
3
⁄
16
” 1” 12”
1
⁄
2
”8
1
⁄
2
”
8” 30
5
⁄
8
”1
1
⁄
2
” 16” 1” 11
5
⁄
16
”
10” 38
5
⁄
8
” 2” 20” 1
1
⁄
4
”14
1
⁄
8
”
12” 46
3
⁄
8
” 24” 1
1
⁄
2
”16
15
⁄
16
”
14” 54
1
⁄
16
” 28” 2” 19
13
⁄
16
”
16” 61
13
⁄
16
” 32” 22
5
⁄
8
”
18” 67
7
⁄
16
” 36” 25
7
⁄
16
”
20” 77
1
⁄
4
” 40” 28
1
⁄
4
”
22” 85” 44” 31
1
⁄
8
”
To locate distance between centers of offset bending marks other than listed in
table A use the following multipliers:
15˚ bend - 3.9
30˚ bend - 2.0
45˚ bend - 1.4
Table A
15˚ Bend 30˚ Bend 45˚ Bend
Conduit Radius Radius
Size Rigid / IMC EMT
1
⁄
2
”3
31
⁄
32
”3
7
⁄
8
”
3
⁄
4
”4
25
⁄
32
”4
29
⁄
32
”
1” 5
9
⁄
16
”5
29
⁄
32
”
1
1
⁄
4
”6
7
⁄
8
”7
3
⁄
32
”
1
1
⁄
2
”7
9
⁄
16
”7
1
⁄
2
”
2” 8
9
⁄
32
”8
9
⁄
16
”
Table B
BEND RADIUS
1
⁄
2
” Rigid 7
3
⁄
4
”1
1
⁄
4
” Rigid 12
3
⁄
4
”
1
⁄
2
” IMC 7
3
⁄
4
”1
1
⁄
4
” IMC 12
1
⁄
2
”
1
⁄
2
” EMT 7
5
⁄
8
”1
1
⁄
4
” EMT 13”
3
⁄
4
” Rigid 9” 1
1
⁄
2
” Rigid 13
1
⁄
2
”
3
⁄
4
” IMC 9” 1
1
⁄
2
” IMC 13
1
⁄
2
”
3
⁄
4
” EMT 8
1
⁄
2
”1
1
⁄
2
” EMT 13
1
⁄
2
”
1” Rigid 10
1
⁄
8
” 2” Rigid 15
3
⁄
4
”
1” IMC 10
1
⁄
8
” 2” IMC 15
1
⁄
2
”
1” EMT 10
3
⁄
8
” 2” EMT 15
1
⁄
2
”
Table C
Conduit Stub-up Conduit Stub-up
Size Set-back Size Set-back
Shoe
Min. 2˝
Stub Length
Set Back
Mark #2
Mark #1
Front Edge of
Clamp Mark #2
Stub to Bottom
of Pipe