Specification
300 V max. building wiring
Capacidad nominal de
300 V Máx. para cableado
en general
Fil de bàtiment de 300 V Max.
2 / 3 #16
2 - 4 #18
2 - 5 #20
3 - 5 #22
1 #14 + 1 #16 / 18
1 #14 + 1 - 3 #20
1 #14 + 1 - 4 #22
1 #16 + 1 / 2 #18
1 #16 + 1 - 4 #20 / 22
1 / 2 #16 + 1 #20 + 1 #22
2 #16 + 1 #18
2 #16 + 1 / 2 #20
2 #16 + 1 - 3 #22
1 #18 + 1 - 4 #20
1 #18 + 3 / 4 #22
1 / 2 #18 + 1 #20 + 1 #22
2 #18 + 1 - 3 #20 / 22
3 #18 + 1 / 2 #20 / 22
4 #18 + 1 #22
1 #20 + 4 #22
2 #20 + 2 / 3 #22
3 #20 + 1 / 2 #22
4 #20 + 1 #22
APPLICATION
Use GB-2 WireGard™ twist-on wire connector in general purpose
applications of 2 or more copper wires. GB-2 connectors feature side
knurling for easy grip.
SPECIFICATIONS
WireGard™ connectors shall feature straight type shell and steel inner
spring and be suitable for connecting copper wire from #22 to #14 AWG.
Spring shall be plated to resist corrosion and have a square profile to
provide secure contact with wires.
Connectors shall be rated for use with 300 V building wire plus be UL listed
and CSA certified for applications up to 105 °C. WireGard™ connectors
must have few turns to meet required torque, meet or exceed UL pull out
and dielectric test requirements.
INSTALLATION INSTRUCTIONS
1. Strip wire 5/16" (7.9 mm). For 6 and 18 gauge stranded wires, strip 3⁄8" (9.5 mm).
2. Pretwisting unnecessary. Hold stripped wires together with ends even.
(Lead stranded wires slightly).
3. Align any frayed strands or conductors.
4. Screw on connector; push wires firmly into connector when starting.
5. To be sold only with installation instructions.
! !
WARNING:
Shut off power before working on a circuit. Use
approved materials and conform to all electrical codes.
CONSTRUCTION
Shell: Polypropylene, Color - Blue
Innerspring: Zinc plated, square profile steel wire
Temperature Rating: 105 °C (221 °F)
WIRE RANGE
#22 to #14 AWG Solid or Stranded conductors
Copper conductors only, 300 V max. building wire
REGULATORY APPROVALS
UL: List for pressure type wire connectors per UL 486C,
file number 61X5. UL94V-2 flame retardant.
WireGard™
Electrical Wire Connector
GB-2
(Blue)
Wire Connector
61X5
DATA SHEET / HOJA DE DATOS / FICHE TECHNIQUE
GB-2 WireGard™
DS-0002
Gardner Bender l Milwaukee, WI 53209 l www.gardnerbender.com l Questions or Comments 800.624.4320
Made in China/Hecho en China/Fabriqué en Chine l ZX427
WIRE COMBINATIONS / COMBINACIONES
DE CABLE / COMBINAISONS DE CABLES
LISTED FOR USE WITH: COPPER TO COPPER
Temperature rating: 105 °C (221 °F) Listed as a
PRESSURE TYPE wire connector for the following
solid and/or stranded wire connections:
CLASIFICADO PARA USARSE CON:
COBRE A COBRE
Especificatión de temperatura: 105 °C (221 °F)
Clasificado como un conector de cable TIPO A
PRESION para uso con las siguientes conexiones
de cable macizo y/o trenzado:
POUR USAGE DE: CUIVRE A CUIVRE
Cote de température: 105 °C (221 °F) Connecteur
A PRESSION pour les combinaisons suivantes de
fils pleins et/ou à brins:
A
B
C
D
E
A B C D E
GB-2
(in) 45/64 11/64 3/16 5/16 25/64
(mm) 17.9 4.4 4.8 7.9 9.9
DIMENSIONS