Installation Instructions
Table Of Contents
- 1 INTRODUCTION
- 2 GENERAL INFORMATION
- 3 INSTALLATION
- 3.1 Target Group
- 3.2 Definition of the Door Hinge (Right of Left Door)
- 3.3 Test Installation
- 3.4 Metallic and Non-Metallic Doors
- 3.5 Bolt Gauge
- 3.6 Door Status Contact
- 3.7 Transportation Guidelines
- 3.8 Replacement after a Burglary Attempt
- 3.9 Measurement Diagrams for Installation
- 3.10 Installation in Lockers with Non-Metallic Doors (Except Glass)
- 3.11 Installation in Lockers with Metallic Doors
- 3.12 Installation in Lockers with Glass Doors
- 4 COMMISSIONING
- 5 CONFIGURATION
- 5.1 General Information
- 5.2 Setup for Configuration in GAT Config Manager
- 5.3 View and Edit the GAT ECO.Side Lock 7000 BA Configuration Settings
- 5.4 Upload Configuration Settings to the GAT ECO.Side Lock 7000 BA
- 5.5 Updating the GAT ECO.Side Lock 7000 BA Firmware
- 5.6 Configuration Settings of the GAT ECO.Side Lock 7000 BA
- 6 OPERATION
- 7 CLEANING AND MAINTENANCE
- 8 TECHNICAL DATA
GAT ECO.Side Lock 7000 BA / NW BA
Technical Data
62
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
www.gantner.com
8.4 Control and Display Elements
Control element: Door contact in lock
Display element: LED (red / green) to indicate the different operating states
8.5 Interfaces
Interface type: USB 2.0
Interface connection: USB type Micro-B
8.6 Housing
Material: Plastic (PC), halogen-free, V0
Color: Dark gray
Weight: Approx. 400 g (14.1 oz.)
Dimensions: 125.2 mm x 100 mm x 25 mm (4.93” x 3.94” x 0.98”)
Break-in resistance capability: DIN 4547-2 class C
8.7 Environmental Conditions
Permitted ambient temperature: -10 °C to +55 °C (14 °F to 131 °F)
Protection type: IP 52
Protection class: III
Environment class
based on VdS 2110: II (conditions in indoor areas)
Compliance: CE, FCC, IC