Installation Instructions
Table Of Contents
- 1 INTRODUCTION
- 2 GENERAL INFORMATION
- 3 INSTALLATION
- 3.1 Target Group
- 3.2 Definition of the Door Hinge (Right of Left Door)
- 3.3 Test Installation
- 3.4 Metallic and Non-Metallic Doors
- 3.5 Bolt Gauge
- 3.6 Door Status Contact
- 3.7 Transportation Guidelines
- 3.8 Replacement after a Burglary Attempt
- 3.9 Measurement Diagrams for Installation
- 3.10 Installation in Lockers with Non-Metallic Doors (Except Glass)
- 3.11 Installation in Lockers with Metallic Doors
- 3.12 Installation in Lockers with Glass Doors
- 4 COMMISSIONING
- 5 CONFIGURATION
- 5.1 General Information
- 5.2 Setup for Configuration in GAT Config Manager
- 5.3 View and Edit the GAT ECO.Side Lock 7000 BA Configuration Settings
- 5.4 Upload Configuration Settings to the GAT ECO.Side Lock 7000 BA
- 5.5 Updating the GAT ECO.Side Lock 7000 BA Firmware
- 5.6 Configuration Settings of the GAT ECO.Side Lock 7000 BA
- 6 OPERATION
- 7 CLEANING AND MAINTENANCE
- 8 TECHNICAL DATA
GAT ECO.Side Lock 7000 BA / NW BA
Technical Data
www.gantner.com
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
61
8
TECHNICAL DATA
8.1 Power Supply
Power supply: 1 x 3.6 V lithium battery, size AA, capacity 2.4 Ah
GANTNER approved battery: EU: Tadiran SL-860/S
US: Tadiran TL-4903/S
Battery lifetime: Up to 10 years* at +20 °C (68 °F)
*depending on usage, configuration, and environmental conditions
8.2 Reading Field
Reader type: Multi-technology RFID reader (LEGIC advant)
Data carriers
Segments and UID: - LEGIC prime
- LEGIC advant
UID only: - ISO 15693
- MIFARE ISO 14443
- Classic (1k and 4k)
- Ultralight
®
- DESFire EV1
®
and EV2
®
- HID iCLASS (13.56 MHz)
Note: It is recommended to have customer specific data carriers approved by
GANTNER before use
Reading field frequency: 13.56 MHz
Maximum sending power: < 500 mW
Reading field range: 5 to 35 mm (0.2´´ to 1.38´´)*
*depending on the installation and type of data carrier
8.3 Memory and Time Management
Data storage: EEPROM with capacity for 150 bookings, data retained during battery
change
Internal clock: Quartz-controlled, real-time clock