Installation Instructions
Table Of Contents
- 1 INTRODUCTION
- 2 GENERAL INFORMATION
- 3 INSTALLATION
- 3.1 Target Group
- 3.2 Definition of the Door Hinge (Right of Left Door)
- 3.3 Test Installation
- 3.4 Metallic and Non-Metallic Doors
- 3.5 Bolt Gauge
- 3.6 Door Status Contact
- 3.7 Transportation Guidelines
- 3.8 Replacement after a Burglary Attempt
- 3.9 Measurement Diagrams for Installation
- 3.10 Installation in Lockers with Non-Metallic Doors (Except Glass)
- 3.11 Installation in Lockers with Metallic Doors
- 3.12 Installation in Lockers with Glass Doors
- 4 COMMISSIONING
- 5 CONFIGURATION
- 5.1 General Information
- 5.2 Setup for Configuration in GAT Config Manager
- 5.3 View and Edit the GAT ECO.Side Lock 7000 BA Configuration Settings
- 5.4 Upload Configuration Settings to the GAT ECO.Side Lock 7000 BA
- 5.5 Updating the GAT ECO.Side Lock 7000 BA Firmware
- 5.6 Configuration Settings of the GAT ECO.Side Lock 7000 BA
- 6 OPERATION
- 7 CLEANING AND MAINTENANCE
- 8 TECHNICAL DATA
GAT ECO.Side Lock 7000 BA / NW BA
Installation
www.gantner.com
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
25
3.11 Installation in Lockers with Metallic Doors
For lockers with metallic doors, the GAT ECO.Side Lock 7000 BA is mounted on the left or right inner locker wall
depending on whether it is a right or left-hinged locker door. Two cutouts must be made in the locker door - one in
the inner door sheet and one in the outer door sheet. The two parts of the GAT NET.Lock Bolt Set 7200 are then
mounted into the locker door. See the diagram below and the following installation instructions.
1. GAT ECO.Side Lock 7000 BA
2. GAT NET.Lock Bolt Set 7200
3. 3 x mounting screws for the GAT ECO.Side Lock 7000 BA
5. Door contact
6. 4 x mounting holes for the GAT NET.Lock BoltSet 7200
7. LED position
8. Cutout for GAT NET.Lock Bolt Set 7200
9. Cutout for label carrier
10. Label carrier
Figure 3.11 - Installation in a locker with metallic, right-hinged door (dimensions in mm – inches shown in brackets)