Installation Instructions
Table Of Contents
- 1 INTRODUCTION
- 2 GENERAL INFORMATION
- 3 INSTALLATION
- 3.1 Target Group
- 3.2 Definition of the Door Hinge (Right of Left Door)
- 3.3 Test Installation
- 3.4 Metallic and Non-Metallic Doors
- 3.5 Bolt Gauge
- 3.6 Door Status Contact
- 3.7 Transportation Guidelines
- 3.8 Replacement after a Burglary Attempt
- 3.9 Measurement Diagrams for Installation
- 3.10 Installation in Lockers with Non-Metallic Doors (Except Glass)
- 3.11 Installation in Lockers with Metallic Doors
- 3.12 Installation in Lockers with Glass Doors
- 4 COMMISSIONING
- 5 CONFIGURATION
- 5.1 General Information
- 5.2 Setup for Configuration in GAT Config Manager
- 5.3 View and Edit the GAT ECO.Side Lock 7000 BA Configuration Settings
- 5.4 Upload Configuration Settings to the GAT ECO.Side Lock 7000 BA
- 5.5 Updating the GAT ECO.Side Lock 7000 BA Firmware
- 5.6 Configuration Settings of the GAT ECO.Side Lock 7000 BA
- 6 OPERATION
- 7 CLEANING AND MAINTENANCE
- 8 TECHNICAL DATA
GAT ECO.Side Lock 7000 BA / NW BA
Installation
www.gantner.com
HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14
23
Installation Requirements for the GAT ECO.Side Lock 7000 BA and Non-Metallic Doors
During installation, please pay particular attention to the following points:
- When the door is pressed shut, ensure there is no gap between the bolt set (2) and the front of the GAT ECO.Side
Lock 7000 BA. Ideally the bolt set should touch the front of the lock (see Figure 3.9).
- The locker door, the bolt set, and the front side of the GAT ECO.Side Lock 7000 BA must be perpendicular and
parallel to each other. If not, the door contact in the GAT ECO.Side Lock 7000 BA can potentially not function
correctly.
- If right and left-hinged locker doors are in use together, please note the correct LED position. The GAT ECO.Side
Lock 7000 BA is mounted upside-down on left doors in comparison to right doors.
Figure 3.10 - LED positions of the GAT ECO.Side Lock 7000 BA for right and left-hinged doors
NOTE! Before installing all locks in a new locker system, a test installation of one lock into a completed locker and
a function check must be performed. See section “3.3 Test Installation”.