Certifications 2
DYNAMIS Batterien GmbH Brühlstr. 15 D-78465 Dettingen / Konstanz Tel. +49 7533 93669-0
info@dynamis-batterien.de www.dynamis-batterien.de Fax +49 7533 93669-91
Version 01.01.2021
Page 4 of 5
Section IX – Accidental Release or Spillage
Steps to Be Taken in Case Material is Released or Spilled:
If the battery material is released, remove personnel from area until fumes dissipate. Provide maximum
ventilation to clear out hazardous gases. Wipe it up with a cloth, and dispose of it in a plastic bag and put
into a steel can. The preferred response is to leave the area and allow the battery to cool and vapors to
dissipate while maximum ventilation is provided. Avoid skin and eye contact or inhalation of vapors.
Remove spilled liquid with absorbent and incinerate.
Batteries that are leakage should be handled with rubber gloves.
Avoid direct contact with electrolyte.
Wear protective clothing and a positive pressure Self – Contained Breathing Apparatus
(SCBA).
Waste Disposal:
It is recommended to discharge the battery to the end, handing in the abandoned batteries to related
department unified, dispose of the batteries in accordance with approved local, state, and federal
requirements.
Section X – Handling and Storage
Safe handling and storage advice:
The battery should not be opened, destroyed or incinerated, since they may leak or rupture
and release to the environment the ingredients that they contain in the hermetically sealed
container.
Do not short circuit terminals or overcharge the battery, force over-discharge, throw into fire or reverse-
charge. Do not crush or puncture the battery, or immerse in liquids.
Store the batteries in dry and cool area (below 30 °C). Store batteries in adequate distance from walls.
Precautions to be taken in Handling and Storing
Avoid mechanical or electrical abuse. Storage preferably in cool, dry and ventilated area, which is subject
to little temperature change. Storage at high temperatures should be avoided.
Do not place the battery near heating equipment, nor expose to direct sunlight for long periods.
Other Precautions
The battery may explode or cause burns, if disassembled, crushed or exposed to fire or high temperatures.
Do not short or install with incorrect polarity.
Apply only suitable equipment for charging and discharging. Do not mix cells and batteries of differing
age or use history, nor different types or sizes within one assembly
Section XI – Exposure Control / Person Protection
Respiratory Protection (Specify Type): In case of battery venting, provide as much ventilation as possible.
Avoid confined areas with venting cells. Respiratory protection is not necessary during normal (specified)
use.
Ventilation: N/A during specified use
Local Exhausts: N/A during spec. use.
Special: N/A
Mechanical (General): N/A during spec. use.
Special: N/A
Other: N/A
Eye Protection: N/A during spec. use.
Protective Gloves: N/A during specified use
Other Protective Clothing or Equipment: N/A
Work / Hygienic Practices: N/A