Certifications 2
DYNAMIS Batterien GmbH Brühlstr. 15 D-78465 Dettingen / Konstanz Tel. +49 7533 93669-0
info@dynamis-batterien.de www.dynamis-batterien.de Fax +49 7533 93669-91
Version 01.01.2021
Page 3 of 5
Section V – Reactivity Data
Stability: Stable Status
Conditions to Avoid: Fire/Heating above specified range (+85 °C), short circuiting tools or solvents,
mechanical/electrical abuse.
Incompatibility (Materials to Avoid): Acids, Water, Metal corroding/Oxidizing materials.
Hazardous Decomposition of By-products: Reaction of water with free electrolyte generates HF.
HF is corrosive and irritant, and can be very harmful in contact
with skin/eyes or when inhalated. Immediate medical attention necessary.
Hazardous Polymerization: Will not occur
In case of leakages: Do not inhalate vapors or gases from the cell. See to proper ventilation with air.
Section VI – Health Hazard Data
Routes of Entry - Normal use
Inhalation: N/A
Skin: N/A
Ingestion: N/A
Health Hazard (Acute and Chronic) / Toxicological information: N/A
Section VII – First Aid Measures
First Aid Procedures (in case of leakages):
In case of battery case rupture, fume or fire evacuate personnel from contaminated area and provide
maximum ventilation with air to clean out fumes and gases. Then spray water onto battery or put battery
into basin with water.
Medical attention is strongly advised in such cases.
Eyes:
Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eye lids.
See to medical aid.
Skin:
Remove contaminated clothes and rinse skin with plenty of water or shower immediately and continue for
15 minutes. Use only soap. Never apply greases or ointments. See to medical aid.
Inhalation:
Remove from exposure and move to fresh air, oxygen if available. Seek medical attention. Ventilate the
contaminated area.
Ingestion:
Drink immediately plenty of water and seek for medical help. Assure that the victim does not aspirate
vomited material by use of personal drainage. Assure that mucus does not obstruct the airway. Do not give
anything by mouth to an unconscious person.
Section VIII – Fire and Explosion Hazard Data
Flash Point (Method Used): N/A
Ignition Temp.: N/A
Flammable Limits: N/A
LEL: N/A
UEL: N/A
Extinguishing Media: Water (Spray or basin), Type D, Carbon Dioxide, Dry Chemical or Foam
Special Fire Fighting Procedures: Self-contained breathing apparatus required
Unusual Fire and Explosion Hazards: Cell may vent if exposed to excessive heat
Do not dispose of battery in fire – may explode.
Do not short – circuit battery – may cause burns.
Hazardous combustion products: CO, CO
2
, Li Oxide fumes, Phosphorous Oxide, HF, PF
3
/PF
5