Gallagher T30 Keypad Reader Installation Note T30 MULTITECH® Keypad Reader, Black: C300490 T30 MULTITECH® Keypad Reader, White: C300491 T30 MIFARE® Keypad Reader, Black: C300495 T30 MIFARE® Keypad Reader, White: C300496 3Ennnn Gallagher T30 Reader Installation Note| DRAFT2 | July 2020 Copyright © Gallagher Group Limited Page 1
Disclaimer This document gives certain information about products and/or services provided by Gallagher Group Limited or its related companies (referred to as "Gallagher Group"). The information is indicative only and is subject to change without notice meaning it may be out of date at any given time.
Contents 1 Introduction ........................................................................................................................................ 4 2 Before you begin ................................................................................................................................. 4 2.1 Shipment contents................................................................................................................... 4 2.2 Power supply .......................................
1 Introduction The Gallagher T30 Keypad Reader is available in a variety of variants. The variant you have purchased determines the available functionality and supported technologies for the reader. The Multi Tech variants C300490 and C300491 support Gallagher mobile credentials, using Bluetooth® low energy technology.
wiring be required, the HBUS 4H/8H Modules and the HBUS Door Module allow multiple HBUS devices to be individually wired to the one physical location. The end devices on the HBUS cable should be terminated using 120 ohms resistance. To terminate the Gallagher Controller 6000, connect the supplied on-board termination jumpers to the Controller. To terminate the Gallagher T30 Keypad Reader, connect the orange (termination) wire to the green (HBUS A) wire.
Cable distance Cable type CAT 5e or better** Cable format* Single terminal connected using HBUS data only in a single cable 4 twisted pair each 2 x 500 m (1640 ft) 0.2 mm2 (24 AWG) BELDEN 9842** 2 twisted pair each 2 x 500 m (1640 ft) (shielded) 0.2 mm2 (24 AWG) Single terminal connected using power and data in a single cable**** 50 m (165 ft) 50 m (165 ft) SEC472 4 x 0.2 mm2 Not twisted pairs (24 AWG) 400 m (1310 ft) 50 m (165 ft) SEC4142 4 x 0.
4 Installation The Gallagher T30 Keypad Reader can be mounted on: • a vertical, rectangular 50 mm x 75 mm (2 in x 3 in) flush box • a BS 4662 British Standard square flush box • any solid flat surface The recommended mounting height for the terminal is 1.1 m (3.6 ft) from the floor level to the centre of the terminal. However this may vary in some countries and you should check local regulations for variations to this height.
4. Drill pilot holes for the four corner fixing holes and the tamper tab. Secure the bezel to the mounting surface using the four corner fixing screws provided. Secure the tamper tab (located in the bezel) to the mounting surface using the remaining fixing screw provided. It is important the four corner fixing screws are used to ensure the terminal is flush with and tight against the mounting surface. Note: It is strongly recommended that you use the screws provided.
5. Connect the terminal tail extending from the facia assembly to the building cable. An HBUS device connects to a Gallagher Controller 6000, Gallagher 4H/8H Module, a Gallagher HBUS Door Module, or a Gallagher HBUS 8 Port Hub. HBUS connections: HBUS connections terminated: To terminate an HBUS device, connect the Orange (HBUS Termination) wire to the Green (HBUS A) wire. PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only. 6.
5 6 LED indications LED (squiggle) HBUS indication 3 Flash (Amber) No communications with the Controller. The terminal screen displays the text 'Connecting...'. 2 Flash (Amber) Communications with the Controller, but terminal is not configured. The terminal screen displays the text 'Not configured'. 1 Flash (Amber) Configured to a Controller, but terminal is not assigned to a door or elevator car.
7 Technical specifications Routine maintenance: Not applicable for this reader. Cleaning: This reader should be cleaned with mild soapy water only. Do not use solvents or abrasives. Voltage: 9 Vdc – 16 Vdc 3 Current : Inactive1 Active2 T30 MIFARE Keypad Reader (at 9 Vdc): 145mA 340mA T30 MIFARE Keypad Reader (at 13.6 Vdc): 92mA 221mA T30 MULTI Keypad Reader (at 9 Vdc): 145mA 340mA T30 MULTI Keypad Reader (at 13.
8 Approvals and Compliance Standards This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
9 Mounting Dimensions IMPORTANT This picture is not to scale, therefore use the measurements provided.