User's Manual
10
Testing the connection between Scale and SmartReader
Once the connection between the SmartReader and Scale is established
you need to test the Scale is receiving the Electronic ID tag data from the
SmartReader.
Activate the SmartReader.1.
Scan an Electronic ID tag.2.
Did the Electronic ID tag number display on the Scale?3.
If • yes, the connection is working.
If • no, the connection is not working.
Check the following:
• that the Scale is set up correctly, including the Scale communications
port.
• that the RS232 plug is fi rmly attached to the correct socket on the
Scale.
Using the SmartReader
Once you have set up the SmartReader you are ready to use it to capture
Electronic ID tag data.
For details on how to set up the SmartReader, see Setting up the SmartReader
HR1 (p 9).
Single-Click the trigger to scan for Electronic ID tags.1.
Move the tip of the SmartReader towards the Electronic ID tag on the 2.
animal.
Once an Electronic ID tag is read the SmartReader beeps and the lamp
illuminates for an extended period.
Repeat steps until all animals Electronic ID tags are read.3.
Notes:
The SmartReader beeps twice if a duplicate tag is read.•
The SmartReader stops scanning for Electronic ID tags once a tag is read. •
You need to Single-Click the trigger to scan for the next Electronic ID tag.
If an Electronic ID tag is not read within the read period the SmartReader •
stops scanning for tags.
Duplicate tags
Each tag read is placed in a temporary storage area referred to as a buffer.
The tag buffer can store a single tag. A tag is retained until the SmartReader
is disconnected from its power source. The duplicate tag checking option can
be altered with the Confi gurator. For further details refer to the SmartReader
HR1 Confi gurator User Manual.