User's Manual

Gallagher SmartReader R Series User Manual
21
The current settings for the connected SmartReader are displayed in the
lower part of the window under the Operational Settings tab:
5. The Dual-Reader mode is set to the default, OFF.
Select Primary to set up the master SmartReader and then select Custom
Wired or Bluetooth.
The Synchronisation settings default, depending on your selection.
6. Click . The settings are transferred to the SmartReader.
7. Click .
8. Unplug the first SmartReader (master) and connect to the other
SmartReader (slave). Repeat from Step 2, to Step 7 to set up the
Secondary SmartReader.
Refer to the
Configurator Online Help:
Operational Settings - Dual-reader
mode
, to set up the Operational Settings screen for the Primary and
Secondary SmartReaders.
Dual-Reader wired installation
This section shows how to connect a master and slave SmartReader using a
custom serial cable, and how to establish a connection between the
SmartReaders and the data collection device. (PC, SmartTSi, Weighscale)
Note: You will need a simple custom serial cable in a "Y" configuration. This
cable is not supplied by Gallagher - you are expected to have a custom cable
made to suit your individual installation.
Procedure
1. Plug the supplied reader to RS-232 cable into the serial port on your data
collection device.