User's Manual
Table Of Contents
Page 11
3E4237 Gallagher T15 Reader | Edion 1 | June 2016
Copyright © Gallagher Group Limited
7 Technicalspecicaons
Roune maintenance: Not applicable for this reader
Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth
Voltage: 9 Vdc - 16 Vdc
Current: Mifare Reader Mul Tech Reader
Idle
1
Maximum
2
Idle
1
Maximum
2
at 9 Vdc 124 mA 175 mA 115 mA 164 mA
at 13.6 Vdc 84 mA 113 mA 100 mA 124 mA
Temperature range: -35 °C to +70 °C
Note: Direct sunlight may increase the internal reader temperature
above the ambient temperature level
Humidity: 0 - 95% non-condensing
3
Environmental protecon: IP68
Impact rang: IK07
Unit dimensions: Height 139 mm (5.47 inches)
Width 44 mm (1.73 inches)
Depth 23 mm (0.9 inches)
Maximum number of readers
on one HBUS cable:
20
1
The reader is idle.
2
Peak current during card read.
3
Gallagher T Series readers are UL humidity tested and cered to 85% and have been independently
veried to 95%.
Note: The current values stated above have been reported using the default conguraon for a reader
in Command Centre. Changing the conguraon may vary the current value.