Page 10
3E3140 Gallagher T20 Terminal Installaon Note | Edion 16 | March 2016
Copyright © Gallagher Group Limited
6. Connect the terminal tail extending from the facia assembly to the building cable. Connect the
wires for the appropriate device you wish to interface, either an HBUS device or a Cardax IV
device, as shown:
Note: T20 Terminals using alarms management funconality and T20 PIV Readers must be
connected as HBUS devices.
HBUS connecons: HBUS connecons terminated:
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
HBUS Device
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
HBUS Device
Note: To terminate an HBUS terminal, connect the Orange (HBUS Terminaon) wire to the Green
(HBUS A) wire.
Cardax IV connecons:
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Device
7. Fit the facia assembly into the base by clipping the small lip, into the top of the base and holding
the top, press the boom of the facia assembly down into the base.
Note: Ensure that there is no pressure upon the wire set as it exits the terminal. Ensure the wire
set does not exit the reader at a sharp angle, as this may compromise the integrity of the wire
set's water seal.
8. Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
hole at the boom of the base to secure the facia assembly.
Note: The Torx Post Security screw needs only to be lightly ghtened.