User's Manual

Page 10
3E3140 Gallagher T20 Terminal Installaon Note | Edion 16 | March 2016
Copyright © Gallagher Group Limited
6. Connect the terminal tail extending from the facia assembly to the building cable. Connect the
wires for the appropriate device you wish to interface, either an HBUS device or a Cardax IV
device, as shown:
Note: T20 Terminals using alarms management funconality and T20 PIV Readers must be
connected as HBUS devices.
HBUS connecons: HBUS connecons terminated:
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
HBUS Device
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
HBUS Device
Note: To terminate an HBUS terminal, connect the Orange (HBUS Terminaon) wire to the Green
(HBUS A) wire.
Cardax IV connecons:
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Device
7. Fit the facia assembly into the base by clipping the small lip, into the top of the base and holding
the top, press the boom of the facia assembly down into the base.
Note: Ensure that there is no pressure upon the wire set as it exits the terminal. Ensure the wire
set does not exit the reader at a sharp angle, as this may compromise the integrity of the wire
set's water seal.
8. Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
hole at the boom of the base to secure the facia assembly.
Note: The Torx Post Security screw needs only to be lightly ghtened.