5. The reader connects to a Gallagher Controller 6000 High Spec PIV, Gallagher 4H/8H HBUS
Module (aached to the Controller 6000 High Spec PIV) or a Gallagher HBUS Door Module
(connected to a Controller 6000 High Spec PIV).
Unplug the reader's terminal block from the PCB. Connect the wires from the building cable to
the terminal block as shown. Plug the terminal block back into the PCB.
HBUS connecon: HBUS connecon terminated:
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS B Brown
HBUS A Green
Building Cable
A B T - +
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS B Brown
HBUS A Green
Building Cable
A B T - +
If the reader is the end device on the HBUS cable, terminate the reader by connecng the Orange
(HBUS Terminaon) wire.
6. Secure the reader cable using the cable retenon peg, as shown in the following diagram.
Plug the reader cable into the connector.
Reader cable retenon peg
Rear of facia
7. Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding
the top, press the boom of the facia assembly down into the bezel.
8. Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
hole below the reader facia.
Note: The Torx Post Security screw needs only to be lightly ghtened.