User's Manual
Page 9
Gallagher T20 Reader
Installaon Note
Document Code: 3E3140
Edion 3, April 2013
Make the connecons from the reader to either the Controller 3000-8R or 3000-4R
as shown:
PB1 and PA1... to... PB4 and PA4 (3000-8R)
PB2 and PA2 (3000-4R)
Gallagher Controller 3000-8R or 3000-4R
Group
1 V OUT
2 0 V
1 DATA 0
2 DATA 1
3 OUT 1
4 OUT 2
PB
PA
Posive Red
Negave Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Posive Red
Negave Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Note: Within each group, you cannot mix Cardax IV Readers with Wiegand Readers.
This is because connecng one Wiegand reader requires all four pins on plug PB.
For example, if you connect a Cardax IV Reader to Port 1 of Group 1, Port 2 of Group
1 can only connect to another Cardax IV Reader.