3E4291 Gallagher T20 Terminal Installaon Note | Edion 1 | August 2016
Copyright © Gallagher Group Limited
10 Technicalspecicaons
Roune maintenance: Not applicable for this terminal.
Cleaning: This terminal should be cleaned with mild soapy
water only. Do not use solvents or abrasives.
Voltage: 9 Vdc - 16 Vdc
Current: Inacve
1
Acve
2
T20 Mifare Terminal (at 9 Vdc): 191 mA 300 mA
T20 Mifare Terminal (at 13.6 Vdc): 140 mA 200 mA
T20 Mul Tech Terminal (at 9 Vdc): 262 mA 335 mA
T20 Mul Tech Terminal (at 13.6 Vdc): 189 mA 282 mA
T20 Alarms Terminal (at 9 Vdc): 140 mA 250 mA
T20 Alarms Terminal (at 13.6 Vdc): 110 mA 190 mA
Temperature range: -30 °C to +70 °C (-22 °F to +158 °F)
Note: Direct sunlight may increase the internal
terminal temperature above the ambient
temperature level.
Humidity: 95% non condensing
4
Environmental protecon: IP66 (independently veried)
Impact rang: IK08 (independently veried)
Unit dimensions: Height 179.5 mm (7.1 in)
Width 95.7 mm (3.8 in)
Depth 23 mm (0.9 in)
Maximum number of readers on one HBUS cable: 20
Maximum number of alarms management
terminals
3
on one Controller 6000:
4
Maximum number of terminals on one Controller
6000:
20
1
The terminal is idle. The screen is on.
2
A card is being read or the screen is at maximum brightness.
3
A terminal is congured for alarm zone management/fence controller management when it has either
Alarm Zones congured on the Alarm Zones properes page or items congured upon its mimic panel.
4
Gallagher T Series readers are UL humidity tested and cered to 85% and have been independently
veried to 95%.
Note: The current values stated above have been reported using the default conguraon of an
HBUS terminal (HBUS Terminal or HBUS Alarms Only Terminal) in Command Centre. Changing the
conguraon may vary the current value.