Edion 3, April 2013
Make the connecons from the reader to either the Controller 3000-8R or 3000-4R
as shown:
PB1 and PA1... to... PB4 and PA4 (3000-8R)
PB2 and PA2 (3000-4R)
Gallagher Controller 3000-8R or 3000-4R
Group
1 V OUT
2 0 V
1 DATA 0
2 DATA 1
3 OUT 1
4 OUT 2
PB
PA
Posive Red
Negave Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Posive Red
Negave Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Note: Within each group, you cannot mix Cardax IV Readers with Wiegand Readers.
This is because connecng one Wiegand reader requires all four pins on plug PB.