User's Manual
Table Of Contents
Page 8
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
4 Installaon
ATTENTION: This equipment contains components that can be damaged by
electrostac discharge. Ensure both you and the equipment are earthed before
beginning any servicing.
The Gallagher T11 Reader is designed to be mounted on vercally orientated electrical ush (gang)
boxes, or any solid at surface. However installaon on metal surfaces, parcularly those with a large
surface area will reduce read range. The extent to which the range is reduced will depend upon the
type of metal surface.
Note: Consideraon should be given to the installaon environment when using Gallagher mobile
credenals, as the Bluetooth® wireless technology read range may be reduced.
The recommended mounng height for the reader is 1.1 m (3.6 ) from the oor level to the centre of
the reader device. However this may vary in some countries and you should check local regulaons for
variaons to this height.
1. Ensure the building cable has been run out through the ush box.
If you are not mounng to a ush box, use the reader bezel as a guide to drill all ve holes. Drill
the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable
will exit the mounng surface) and the four xing holes.
2. Run the building cabling out through the centre hole and through the reader bezel.
3. Secure the bezel to the ush box using the two 6-32 UNC screws provided. It is important the
reader bezel is ush with and ght against the mounng surface.
If you are not mounng to a ush box, secure the bezel to the mounng surface using the four
xing screws provided.
Note: It is strongly recommended that you use the screws provided. If an alternave screw is
used, the head must be no larger nor deeper than that of the screw provided.
Note: Ensure the centre hole allows the cable to run freely out through the mounng surface, so
that the reader facia can clip into the bezel.
Building cable
6-32 UNC screw
6-32 UNC screw
Bezel
4. Connect the reader tail extending from the facia assembly to the building cable. Connect the
wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV
Reader, as shown in the following diagrams.
Note: Gallagher PIV and mobile credenal readers must be connected as HBUS Readers.