User's Manual
Page 8
Gallagher T10 Mifare Reader
Edi on 8 | Part Number: 3E2453
November 2012
Installa on Note
Make the connec ons from the Gallagher T10 Mifare Reader to either the Gallagher
Controller 3000-4R or 3000-8R as shown:
PB1 and PA1... to... PB2 and PA2 (3000-4R)
PB4 and PA4 (3000-8R)
Gallagher Controller 3000-4R or 3000-8R
Group
1 V OUT
2 0 V
1 DATA 0
2 DATA 1
3 OUT 1
4 OUT 2
PB
PA
Posi ve Red
Nega ve Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Posi ve Red
Nega ve Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Note: Within each group, you cannot mix Cardax IV Readers with Wiegand Readers.
This is because connec ng one Wiegand Reader requires all four pins on plug PB.
For example, if you connect a Cardax IV Reader to Port 1 of Group 1, Port 2 of Group
1 can only connect to another Cardax IV Reader.