User's Manual
Page 3
Gallagher T10 Mifare Reader
Installa on Note
Part Number: 3E2453 | Edi on 8
November 2012
Distance between Proximity Readers
The distance separa ng any two proximity readers must not be less than 200 mm
(8 inches) in all direc ons.
200 mm
When moun ng a proximity reader on an internal wall, check that any reader fi xed
to the other side of the wall is not less than 200 mm (8 inches) away.
200 mm
InstallaƟ on
The Gallagher T10 Mifare Reader is designed to be mounted on any solid fl at
surface. However installa on on metal surfaces, par cularly those with a large
surface area will reduce read range. The extent to which the range is reduced will
depend upon the type of metal surface.
The recommended moun ng height for the reader is 1.1 m (3.6 ) from the fl oor
level to the centre of the reader device. However this may vary in some countries
and you should check local regula ons for varia ons to this height.
1. Using the drill template at the back of this installa on note as a guide, drill all
three holes. Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre
hole for which the building cable will exit the moun ng surface) and the two
fi xing holes.
2. Run the building cabling out through the centre hole and through the reader
base.
3. Secure the base to the moun ng surface using the two fi xing screws provided.
It is important the base of the reader is fl ush with and ght against the
moun ng surface.
Note: Ensure the centre hole allows the cable to run freely out through the
moun ng surface, so that the reader facia can clip into the base.