User's Manual

Part number 3E1100 R12 9
June 2007
Connecting to the Cardax FT URI
Connect the cables to the socket as shown.
Prox Plus Mifare Connector
4
3
2
1
GND
OUTPUTS
OUTPUTS
DET
COMMS
COMMS
5/12V
Plug P1 or P2
Cardax FT Universal Reader Interface
Red
White
Blue
Black
Connect the Prox Mifare Series (Teardrop) reader connector to either the P1 or
P2 plug on the Cardax FT URI. Refer to the Cardax FT URI component layout
diagram, next, for the location of the plugs.
Q31
D18
U19
T1
R7
R50
R55
R52
R51
R53
R54
JP2
D13
D23
D24
D1
D2
D3
D4
D6
D5
D11
D10
D25
D20
D19
D17
D15
Q7
Q2
D12
D16
D14
Q30
Q29
9
210
1
P8
JP1
SW1
E
Q26
Q27
COMM
NC NO
COIL
RLY2
COMM
NC NO
COIL
D28
D27
D26
R80
R79
R95
R96
R81
R94
D21
Q28
D22
Q41
(c)1999 PEC(New Zealand) Ltd
REV[A][B][C]
22825V2 Assy 22826
5V
12V
P4
Balanced Inputs
pin 1 = Input1
pin 2 = Input 2
pin 3 = Input 3
pin 4 = Input 4
pin 5 = Input 5
pin 6 = Input 6
pin 7 = Ground
P7
Relay Outputs
pin 1 = R1 Normally closed
pin 2 = R1 Normally open
pin 3 = R1 Common
pin 4 = R2 Normally closed
pin 5 = R2 Normally open
pin 6 = R2 Common
pin 7 = Ground
P5
Power & Comms
pins 1 & 2 = RS485
pin 3 = 13.6 V ± 15%
pin 4 = 0V
SW1
Unit address
Set unit number
P8
Diagnostic port
P6
13.6 V ± 15%out
pin 1 = 13.6 V ± 15%
pin 2 = Ground 3A fused
P3
Keypad
pin 1 = Row1
pin 2 = Row 2
pin 3 = Row 3
pin 4 = Row 4
pin 5 = Column1
pin 6 = Column2
pin 7 = Column3
pin 8 = Ground
P2
Non-CardaxFT
Reader 2
pin 1 = 5/12 V power
pin 2 = DataA
pin 3 = DataB
pin 4 = Card detect
pin 5 = LED output
pin 6 = Beeper output
pin 7 = Ground
P1
Non-CardaxFT
Reader 1
pin 1 = 5/12 V power
pin 2 = DataA
pin 3 = DataB
pin 4 = Card detect
pin 5 = LED output
pin 6 = Beeper output
pin 7 = Ground
F1
13.6 V Input Fuse
Rating = 500mA
F2
13.6 V Output Fuse
Rating = 3A
D17 and D21
Relay state indicators
LED on = Energised
LED off = De-energised
D18
Run LED
D10
Comms LED
flashing = communicating with
FT Controller
JP1
Reader Voltage select
= 5V (200mA total)
= 12V (1A total)
P1
P2