Installation Note Cardax Prox Plus 125 Reader CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing.
Power Supply Requirements The Prox Plus 125 reader requires a supply of 13.6 V DC +/- 15% at 200 mA. Prox Plus 125 readers require a good quality linear power source. Note: Switch mode power supplies are not recommended as they may reduce the read range of the Prox Plus 125 reader. Cabling Use 4 core, 0.2 mm2 (AWG 24) cabling with a maximum, nominal capacitance of 120 pf/m. The maximum external diameter of the cable must not exceed 5mm (1/5 inch).
Mounting Distance Between Proximity Readers The distance between any 2 proximity readers must be greater than 200mm in all directions. Please note that 200mm in all directions includes the distance through walls.
Mounting Note: The Prox Plus 125 reader has been designed to metric specifications therefore any imperial measurements provided are approximate only. The Prox Plus 125 reader is designed to be mounted on any solid flat surface including metal surfaces. The recommended mounting height for the Prox Plus 125 reader is 1100mm from floor level to the centre of the reader unit. However this may vary in some countries and you should check local regulations for variations to this height.
Removing the Facia To remove the facia from the Prox Plus 125 base you need the plastic de-latching tool (Part No. C41612) shown below. Slide the de-latching tool firmly under the bottom of the Prox Plus 125 reader. Hold the top of the reader with your fingers and squeeze the de-latching tool up, towards the top of the reader with your thumb. Lift the facia away from the base.
Connecting to the URI The Prox Plus 125 reader can connect to either a Cardax IV or CardaxFT URI. Use the cable terminating tool to connect the cables to the socket as described in the following sections. Pin number 4 of the Prox Plus 125 connector feeds into the cable terminating tool first. The pin numbers are marked on the connector. Connecting to the CardaxFT URI Connect the cables to the socket as shown.
Connecting to the Cardax IV URI Connect the cables to the socket as shown. Note: The colours shown in the diagram below are those used in the cable assembly (Part No. 190810) which may be ordered already assembled.
Initialisation Initialising with the CardaxFT URI The CardaxFT URI must be allocated a unique unit address which is set up at the CardaxFT URI and at the Command Centre FT Server. Refer to the CardaxFT Universal Reader Interface Installation Note and the Command Centre FT documentation. Note: When configuring Command Centre FT you will need to know the plug (P1 or P2) to which the Prox Plus 125 reader is connected.
Cardax IV URI Settings Please refer to the diagram below for the location of the URI components. Fuse Fuses (Reader Power (Relay Supply) Contacts) Ground COM B COM A Power Comms & Power P1 Lithium Battery Lithium Battery Jumper J1 D8 Comms In F1 F2 D10 Ground GND Normally Open N.O. Relay Common COM Normally Closed N.C.
Tamper the URI by opening the door of the cabinet. This releases the tamper switch. The URI has a set of six jumpers grouped into two sets of three. One group is labelled ENTRY and the other is labelled EXIT. ENTRY jumpers set the voltage and card type of the reader connected to plug P5. EXIT jumpers set the voltage and card type of the reader connected to plug P4.
Set DIPSW1 as follows: Switches 1 2 3 4 5 6 7 8 On 1 2 4 8 16 32 Off Unit Addresses Initialise 1 door software = liftcar reader 2 door software = keypad on door 2 Normal 1 door software = door reader 2 door software = no keypad on door 2 Set DIPSW2 as follows, where 0 = OFF and 1 = ON: URI Software vW6.10, vW7.10, vW9.10 or later versions.
Set DIPSW1:7 to ON. Present a Prox 125 card to the Prox Plus 125 reader. Note:You must present the card within 30 seconds of setting DIPSW1:7 to ON. If you are initialising with two readers connected to the URI, you should present the card to the reader on URI plug P5. Set DIPSW1:7 to OFF The green LED (D44) will begin flashing continuously. The other red LED (D10) will flash each time the URI replies to a poll from the Commander. Replace the lithium battery jumper (J1).
Icons The Prox Plus 125 reader displays the following icons on the liquid crystal display (LCD) to indicate the access status of the zone controlled by the reader.