User's Manual
Table Of Contents
- Contents
- Overview
- Controller Notation
- Servo and Stepper Motor Notation:
- Command Descriptions
- Servo Update Rates
- Commands which are not Allowed when Operating in Fast Mode:
- #
- $
- & |
- ( )
- ;
- [ ]
- + - * /
- <, >, =, <=, >=, <>
- =
- AB
- @ABS[n]
- AC
- @ACOS[n]
- AD
- AF
- AI
- AL
- AM
- @AN[n]
- AO
- AP
- AR
- AS
- @ASIN[n]
- AT
- @ATAN[n]
- #AUTO
- #AUTOERR
- AV
- BA
- BB
- BC
- BD
- BG
- BI
- BK
- BL
- BM
- BN
- BO
- BP
- BS
- BV
- BZ
- CB
- CC
- CD
- CE
- CF
- CI
- CM
- #CMDERR
- CN
- CO
- @COM[n]
- #COMINT
- @COS[n]
- CR
- CS
- CW
- DA
- DC
- DE
- DL
- DM
- DP
- DT
- DV
- EA
- EB
- EC
- ED
- EG
- EI
- ELSE
- EM
- EN
- ENDIF
- EO
- EP
- EQ
- ER
- ES
- ET
- FA
- FE
- FI
- FL
- @FRAC[n]
- FV
- GA
- GN
- GM
- GR
- HM
- HX
- IA
- IF
- IH
- II
- IL
- IN
- @IN[n]
- #ININT
- @INT[n]
- IP
- IT
- IV
- JG
- JP
- JS
- KD
- KI
- KP
- KS
- LA
- LE
- _LF*
- LI
- #LIMSWI
- LL
- LM
- _LR*
- LS
- LV
- LZ
- MB
- MC
- #MCTIME
- MF
- MG
- MO
- MR
- MT
- NB
- NF
- NO
- NZ
- OB
- OC
- OE
- OF
- OP
- @OUT[n]
- P1CD P2CD
- P1CH P2CH
- P1NM P2NM
- P1ST P2ST
- #POSERR
- PA
- PF
- PR
- QD
- QR
- QU
- QZ
- RA
- RC
- RD
- RE
- REM
- RI
- RL
- @RND[n]
- RP
- RS
-
R S -
R V - SA
- SA n
- SB
- SC
- SH
- @SIN[n]
- SL
- SP
- @SQR[n]
- ST
- @TAN[n]
- TB
- TC
- #TCPERR
- TD
- TE
- TH
- TI
- TIME*
- TL
- TM
- TP
- TR
- TS
- TT
- TV
- TW
- UI
- UL
- VA
- VD
- VE
- VF
- VM
- VP
- VR
- VS
- VT
- WC
- WH
- WT
- XQ
- ZR
- ZS
- Index

84 ● EP DMC-1400 Series Command Reference
EP
FUNCTION: Cam table master interval and phase shift
DESCRIPTION:
The EP command defines the ECAM table master interval and phase shift. The interval m is
the difference in master position between table entries. The phase shift n instantaneously
moves the graph of slave position versus master position left (negative) or right (positive)
and is used to make on-the-fly corrections to the slaves. Up to 257 points may be
specified.
ARGUMENTS: EP m,n where
m is the master interval and is a positive integer in the range between 1 and 32,767 master
counts. m cannot be changed while ECAM is running.
M = ? Returns the value of the interval m.
n is the phase shift and is an integer between -2,147,483,648 and 2,147,483,647 master
counts. m can be changed while ECAM is running.
USAGE:
While Moving Yes Default Value 256,0
In a Program Yes Default Format
Command Line Yes
Can be Interrogated Yes
Used as an Operand Yes (m only)
Controller Usage
ALL
OPERAND USAGE:
_EP contains the value of the interval m.
RELATED COMMANDS:
EB Enable Ecam
EG Engage Ecam
EM Specify Ecam Cycle
EQ Ecam quit
ET Electronic CAM table
EXAMPLES:
EP 20 Sets the cam master points to 0,20,40 . . .
D =_EP Set the variable D equal to the ECAM internal master interval
EP,100 Phase shift all slaves by 100 master counts