Lubrication
In order to ensure perfect performances of the machine, it is necessary to
Lubricate the brew group. Refer to the following table for the frequency of
lubrication.
Frequency of use Number of daily prepared beverages Frequency of lubrication
Low 1-5 Every 4 months
Regular 6-10 Every 2 months
High >10 Every month
1 Switch o the appliance and unplug it.
2 Remove the brew group and rinse it using lukewarm water (see “Brew
Group Cleaning under Running Water”).
3 Spread a thin layer of lubricant around the inserting pin in the lower part
of the brew group.
4 Spread a thin layer of lubricant onto the guides on both sides (see the
gure).
5 Reinsert the brew group (see “Reinserting the Brew Group”).
You can use the tube of lubricant many times.
Cleaning the Milk Carafe
Quick Clean of the Carafe
After preparing a milk-based beverage, the display shows the icon for the
cleaning of the carafe.
1 When the display shows the icon for the cleaning of the carafe, press
the OK button if you wish to perform a cleaning cycle. The cycle can be
enabled within 10 seconds.
2 Remove the cup with the beverage and place a container under the milk
dispensing spout.
Note: ensure that the milk dispensing spout has been removed.
3 Press the OK button to start dispensing hot water.