Specification Sheet
AW 442 720
Stainless steel
Width 48" (120 cm)
Air extraction/Air recirculation
Without blower. (Choose from
400 series AR400743 internal,
AR400742 inline or AR401742
remote blower.)
Duct cover not included.
AW 442 760
Stainless steel
Width 63" (160 cm)
Air extraction/Air recirculation
Without blower. (Choose from
400 series AR400743 internal,
AR400742 inline or AR401742
remote blower.)
Duct cover not included.
Installation accessories
for air extraction mode
AD 442 012
Stainless steel duct cover,
length: 24 ⁷⁄₁₆", for 7' 9" – 8' 6"
ceiling heights (2.35 – 2.60 m).
AD 442 022
Stainless steel duct cover,
length: 33 7⁄8", for 8' 6" – 10' 2"
ceiling heights (2.60 – 3.10 m).
Installation accessories
for air recirculation mode
AD 442 112
Stainless steel duct cover,
length 24 ⁷⁄₁₆", for 7' 9" – 8' 6"
ceiling heights (2.35 – 2.60 m).
AD 442 122
Stainless steel duct cover,
length: 33 7⁄8", for 8' 6" – 10' 2"
ceiling heights (2.60 – 3.10 m).
Optional accessories
AA 442 110
2 activated charcoal filter with high
efficient odor reduction due to
increased surface. For air recirculation
module AA 442 810
AD 442 392
Stainless steel ceiling collar,
covers screws on duct cover and
uneven gaps of ceilings that are not
completely flat.
AA 442 810
Air recirculation module inclusive
2 activated charcoal filters with high
efficient odor reduction due to
increased surface
For air recirculation.
Can be combined with island and
wall-mounted hood AI/AW 442.
Combinable with:
All Vario cooktops 400 series
All Vario cooktops 200 series
All cooktops 400 series
All cooktops 200 series
Good to know:
the hood has to be larger thanthe
cooktop(s).
400 series wall hood
AW 442
– Professional technology hood
combined with classic
Gaggenau design
– Highly efficient extraction of
cooking vapors due to a large
vapor collection area
– Comes without blower, can be
combined with (BLDC) blowers
– Angled baffle filter with high
grease absorption
– Automatic function, sensor-
controlled power adjustment
depending on the build-up of
cooking vapors
– Dimmable, neutral white LED
lighting for ideal illumination of the
cooktop
– Air extraction or air recirculation
system
– Air recirculation module with
activated charcoal filter: quiet and
highly efficient recirculation
solution with odor reduction as in
air extraction mode, and long
replacement intervals.
Features
2 control panels.
3 electronically controlled power levels
and 1 intensive mode.
Automatic function with sensor-
controlled run-on function.
Grease filter saturation indicator.
Baffle filter, dishwasher-safe.
Neutral white surface LED light
(3,500 K), continuously dimmable.
Lamp output 3x 10 W (48") /
4x 10 W(63").
Illuminance 1,110 lx (48") /
1,010 lx (63").
Easy mounting system for simple
installation and alignment.
Planning notes
For recirculation, use internal blower
AR400743.
The two-part duct cover must be
ordered as an installation accessory.
Connection to the respective
appliances via network cable.
Minimum clearance above gas or
induction cooktops is 30".
Air air recirculation module with 2
activated charcoal filters is installed
in the inner duct cover. Special
recirculation duct covers are available
for this.
Rating
Total rating: 40 W (48") / 50 W (63").
Total Amps: 10 (48") / 15 (63")
120 V / 60 Hz
Connecting cable 35" with plug.
Air extraction:
*
With air extraction duct cover AD 442 012 suitable for ceiling heights
of 7' 9" (2.35 m) to 8' 6" (2.60 m).
**
With air extraction duct cover AD 442 022 suitable for ceiling heights
of 8' 6" (2.60 m) to 10' 2" (3.10 m); Specifications refer to a distance
from floor to lower chimney edge of 5' 2" (1.60 m).
Air extraction
outlet
Outlet
13
3
/
4
"
(350)
14
9
/
16
"
(370)
12
3
/
16
" (310)
*16
15
/
16
"
(430)
**26
3
/
4
"
(680)
16
13
/
16
"
(427)
21
5
/
8
"
(550)
4"
(102)
14
7
/
16
"
(367)
8
11
/
16
"
(220)
8
11
/
16
" (220)
12
3
/
8
"
(315)
12
3
/
8
" (315)
*28
3
/
8
"
(720)
39
3
/
8
"
(1000)
–
–
**37
13
/
16
"
(960)
14
7
/
8
"
(378)
35
7
/
16
"
(900)
59
1
/
16
"
(1500)
–
–
47
1
/
4
"/63"
(1200/1600)
*
With air recirculation duct cover AD 442 112 suitable for ceiling heights
of 7' 9" (2.35 m) to 8' 6" (2.60 m).
**
With air recirculation duct cover AD 442 122 suitable for ceiling heights
of 8' 6" (2.60 m) to 10' 2" (3.10 m); Specifications refer to a distance
from floor to lower chimney edge of 5' 6" (1.60 m).
Outlet
Air recirculation:
13
3
/
4
"
(350)
14
9
/
16
"
(370)
12
3
/
16
" (310)
16
13
/
16
"
(427)
21
5
/
8
"
(550)
47
1
/
4
"/63"
(1200/1600)
4"
(102)
14
7
/
16
"
(367)
8
11
/
16
"
(220)
8
11
/
16
"
(220)
12
3
/
8
"
(315)
12
3
/
8
" (315)
*28
3
/
8
"
(720)
39
3
/
8
"
(1000)
–
–
**37
13
/
16
"
(960)
14
7
/
8
"
(378)
35
7
/
16
"
(900)
59
1
/
16
"
(1500)
–
–
*16
15
/
16
"
(430)
**26
3
/
4
"
(680)
8
9
/
16
"
(218)
11
1
/
8
"
(282)
9
15
/
16
"
(252)
9
9
/
16
"
(243)
ø
6
"
(ø 150)
12
13
/
16
"
(326)
13
5
/
16
"
(338,5)
Air recirculation
module
Air recirculation module AA 442 810
Numbers indicated
inside parenthesis ( ) = mm
www.gaggenau.com/us
Revised: June 2021
www.gaggenau.com/us
Revised: June 2021