Installation Instructions

Table Of Contents
18
Models with air recirculation mode
4 Place both parts of the lower flue duct on the
appliance such that they fit together.
5 Fit the grease filter.
Additional switching output
9 WARNING
Work must only be carried out on the additional
switching output by a qualified electrician in
accordance with the country-specific
requirements and standards.
The appliance has an additional switching output X16
(potential-free contact) that can be used to connect
other appliances, such as a ventilation system that is
available at the installation site. The contact is closed
when the blower is switched on, and is opened when
the blower is switched off.
The switching output is located under a cover. Maximum
switching power 30 V/1 A (AC/DC). The signal that is
connected to the contact must correspond to class of
protection 3.
Connection for window contact switch
AA 400 510
Work on the connection for the window contact switch
must only be carried out by a qualified electrician in
accordance with the requirements and standards of the
country in which in the appliance is being used.
The appliance has a connection (X17) for a window
contact switch. The window contact switch can be flush
mounted or surface mounted. You will receive the