Quick Reference Guide for Specifiers
1414
ROOF COATINGS & LIQUID-APPLIED MEMBRANES
CASE STUDY 1
Texas A&M University Corps of Cadets, College Station, TX
Contractor: Absolute Roofing & Waterproofing — AbsoluteRoofTX.net
Building Owner: Texas A&M University
Job Size: Over 100,000 square feet Completion Date: June 2017
The Corps of Cadets Halls are on-campus
housing for approximately 2,600 students
at Texas A&M University. The halls were
constructed in 1939 and were referred to
at the time as the “new area.” Today, Corps
Halls is referred to as the Corps Quadrangle
or “Quad” for short, and is located across the
field where the Corps of Cadets train.
This project consisted of the demolition of the
entire roof and interior of nine existing Corps
of Cadets dorms. The contractor was tasked
with installing a very difficult tapered system
and ½" primed DensDeck
®
Roof Board to
80-year-old concrete.
The project was originally awarded using a
different system. Due to the large number of
roof penetrations and the over abundance
of other trades working on the roof, we
suggested going with the HydroStop
®
PremiumCoat
®
System. This would allow
"drying in" of the roof with HydroStop
®
Foundation Coat and Fabric, which would
allow other trades to complete their work
for a few months while walking on the
partially completed roof system. The
contractor would then come back in and
repair any damaged areas with HydroStop
®
Foundation Coat and Fabric, and then build
up to the required mil thickness needed
(for warranty) with the appropriate coats of
HydroStop
®
Finish Coat. The GC liked the
idea but A&M was not sold on it. The day that
GAF acquired Quest Construction Products is
the day the HydroStop
®
PremiumCoat
®
System
solution was approved by Texas A&M.
At one point, this project had 437 workers
onsite working on multiple buildings at a time.
The staging areas were small to nonexistent,
and this led to a logistical challenge throughout
the project. Every load and movement on
the grounds had to have a flagger at all
times, and deliveries were scheduled a
week in advance.
“ The end result and the product we turned
over to A&M was amazing. It was the perfect
application for the amount of penetrations on
each roof.” — Barry Muise, Director
of Construction
Note: DensDeck
®
is a registered trademark of Georgia Pacific.
© Slyworks Photography, All Rights Reserved.
• Preserve and protect challenging exterior surfaces
such as low-slope roofs and walls
• Resist UV degradation, water permeation, cracking,
and peeling
• Are backed by a warranty of up to 20 years*
• Offer acrylics, silicones, fluoropolymers,
and urethanes
Find Coating Solutions That…
HydroStop
®
Liquid-Applied Membranes
& United Coatings
™
Products
Challenge:
A liquid-applied roofing system is comprised of
multiple components — including liquid-applied
coatings and mesh membranes, or any combination
thereof — that cure together to form a fully adhered,
seamless, and self-flashing membrane.
Performance
• Monolithic design to prevent points of failure and
protect against leaks
• Products with a warranty of up to 20 years*
Versatility
• Offers a wide range of solutions including acrylics,
silicones, fluoropolymers, and urethanes
• Suitable for repairing and restoring roofing projects
that don’t require a tear-off
• Meets ASTM D6083 Standard Specification for
Liquid Applied Acrylic Coating Used in Roofing
• Many can be installed while occupants are in
the building
Energy Savings
• HydroStop
®
PremiumCoat
®
System, when using
HydroStop
®
PremiumCoat
®
Finish Coat in White,
can be used to comply with Title 24 cool roof
requirements. HydroStop
®
PremiumCoat
®
System
is also UL Listed to ANSI/UL 790 Class A Fire
Resistance for Roof Coverings, FM Approved, and
Miami-Dade County Product Control Approved
The GAF HydroStop
®
PremiumCoat
®
System is a
fabric-reinforced acrylic elastomeric system that
is intended for re-cover and reroof applications
and can be used over a variety of substrates.
It's made using high-quality raw materials and
forms a flexible, UV-resistant membrane. This
liquid-applied membrane is fully reinforced with
a tough nonwoven polyester fabric, designed for
roofing and flashing applications of many types.
HydroStop
®
PremiumCoat
®
System, when using
HydroStop
®
PremiumCoat
®
Finish Coat, meets or
exceeds ASTM D6083 for items such as flexibility,
mechanical properties, and adhesion.
HydroStop
®
liquid-applied roof systems are
assembled onsite, forming a fully adhered,
seamless membrane that meets the requirements
of FM 4470 testing, which includes resistance to
hail, foot traffic, wind uplift, and most importantly,
water leakage. Refer to www.FMapprovals.com/
RoofNav for actual FM Approved assemblies.
HydroStop
®
PremiumCoat
®
Systems feature:
• Versatile solutions for unique projects
• Low maintenance
• Seamless and self-flashing
• Excellent UV and weather resistance
• High solar reflectivity and thermal emissivity
(White and Cotton only)
HydroStop
®
PremiumCoat
®
Systems also:
• Can contribute toward satisfying Credits under
LEED
®
v3 and LEED
®
v4. See the GAF LEED
®
playbook at www.gaf.com/green for details.
• Can be used to comply with Title 24 roofing
product requirements (White and Cotton only)
Solution:
Note: LEED
®
— an acronym for Leadership in Energy and Environmental Design
™
— is a registered trademark of the U.S. Green Building Council.
*See applicable warranty for complete coverage and restrictions.
15