SDS

Material name: ACRYLEX 400 PRIMER
Version #: 6 Revision date: 08-30-2016
SDS 3087
SDS US
3 / 9
Methods and materials for
containment and cleaning up
This material is classified as a water pollutant under the Clean Water Act and should be prevented
from contaminating soil or from entering sewage and drainage systems which lead to waterways.
Large Spills: Stop the flow of material, if this is without risk. Dike the spilled material, where this is
possible. Cover with plastic sheet to prevent spreading. Absorb in vermiculite, dry sand or earth
and place into containers. Following product recovery, flush area with water.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination.
Never return spills to original containers for re-use. For waste disposal, see section 13 of the SDS.
Environmental precautions
Avoid release to the environment. Prevent further leakage or spillage if safe to do so. Avoid
discharge into drains, water courses or onto the ground. Inform appropriate managerial or
supervisory personnel of all environmental releases.
7. Handling and storage
Precautions for safe handling
Obtain special instructions before use. Do not handle until all safety precautions have been read
and understood. Avoid breathing mist or vapor. Avoid contact with eyes, skin, and clothing. Avoid
prolonged exposure. Should be handled in closed systems, if possible. Provide adequate
ventilation. Wear appropriate personal protective equipment. Avoid release to the environment.
Observe good industrial hygiene practices.
Conditions for safe storage,
including any incompatibilities
Store locked up. Store in original tightly closed container. Store away from incompatible materials
(see Section 10 of the SDS).
8. Exposure controls/personal protection
Occupational exposure limits
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
Components Type Value
Form
Calcium Carbonate (CAS
1317-65-3)
Titanium Dioxide (CAS
13463-67-7)
ZINC OXIDE (CAS
1314-13-2)
US. ACGIH Threshold Limit Values
PEL 5 mg/m3 Respirable fraction.
15 mg/m3 Total dust.
PEL 15 mg/m3 Total dust.
PEL 5 mg/m3 Respirable fraction.
5 mg/m3 Fume.
15 mg/m3 Total dust.
Components Type Value
Form
PARAFFINIC PETROLEUM
OIL (CAS 64742-54-7)
Titanium Dioxide (CAS
13463-67-7)
ZINC OXIDE (CAS
1314-13-2)
TWA 5 mg/m3 Inhalable fraction.
TWA 10 mg/m3
STEL 10 mg/m3 Respirable fraction.
TWA 2 mg/m3 Respirable fraction.
US. NIOSH: Pocket Guide to Chemical Hazards
Type
Value
Form
TWA
5 mg/m3
Respirable.
10 mg/m3
Total
Ceiling
15 mg/m3
Dust.
STEL
10 mg/m3
Fume.
TWA
5 mg/m3
Fume.
5 mg/m3
Dust.
US. Workplace Environmental Exposure Level (WEEL) Guides
Components Type Value
Form
Propylene Glycol (CAS
57-55-6)
TWA 10 mg/m3 Aerosol.
Biological limit values
No biological exposure limits noted for the ingredient(s).