Instructions / Assembly
INSTALLATION INSTRUCTIONS
·
INSTRUCCIONES DE INSTALACIÓN
·
INSTRUCTIONS D’INSTALLATION
1.
Quality You Can Trust… From
North America’s Largest Roofing Manufacturer!
™
¡
Calidad En La Que Usted Puede Confiar... Del
Fabricante De Techos Más Grande De Norteamérica!
™
Une Qualité à Laquelle Vous Pouvez Vous Fier...
du Plus Gros Fabricant de Toitures en Amérique du Nord!
MC
GENERAL INSTRUCTIONS
t300'%&$,4Use minimum 3/8" (10mm) plywood or OSB decking as recommended by APA-The Engineered Wood Assn. Wood decks must
be well-seasoned and supported having a maximum 1/8" (3mm) spacing, using minimum nominal 1"(25mm) thick lumber, a maximum 6"
(152mm) width, having adequate nail-holding capacity and a smooth surface. Do NOT fasten shingles directly to insulation or insulated deck
unless authorized in writing by GAF. Roof decks and existing surfacing material must be dry prior to application of shingles.
t6/%&3-":.&/5-&",#"33*&3Install GAF leak barrier at the eaves in localities where leaks may be caused by water backing up behind
ice or debris dams.
t6/%&3-":.&/5300'%&$,1305&$5*0/Underlayment beneath shingles has ma
ny benefits, including helping to prevent wind-driven
rain from reaching the interior of the building and to prevent sap in some wood decking from reacting with asphalt shingles. Underlayment
is also required by many code bodies and is required to maintain the shingles’ UL Class A fire rating. When an underlayment is installed, use
a breather-type underlayment, such as GAF Shingle-Mate
®
or Deck-Armor
™
underlayments. GAF Tiger Paw
™
underlayment, with its moisture
control design, can also be used. Always have a design professional review ventilation requirements when using a moisture control
design underlayment.
t'"45&/&34Use only zinc-coated steel or aluminum, 10-12 gauge, barbed, deformed or smooth shank roofing nails with heads 3/8" (10mm)
to 7/16" (12mm) in diameter. Fasteners should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through the plywood
decks. Fasteners must be driven flush with the surface of the shingle. Overdriving will damage the shingle. Raised fasteners will interfere with
the sealing of the shingles and can back out.
t"41)"-51-"45*$$&.&/5Use asphalt plastic cement conforming to ASTM D4586 Type I or II.
t8*/%3&4*45"/$&)"/%4&"-*/(These shingles have a special thermal sealant that firmly bonds the shingles together after applica
tion
when exposed to sun and warm temperatures. Shingles installed in fall or winter may not seal until the following spring. If shingles are damaged
by winds before sealing or are not exposed to adequate surface temperatures, or if the self-sealant gets dirty, the shingles may never seal.
Failure to seal under these circumstances results from the nature of self-sealing shingles, and is not a manufacturing defect. If shingles are
to be applied during PROLONGED COLD periods or in areas where airborne dust or sand can be expected before sealing occurs, the shingles
MUST be hand sealed. See Nailing Instructions / Hand Sealing.
t."/4"3%"/%45&&14-01&"11-*$"5*0/4For roof slopes greater than 21" per foot (1750mm/m), shingle must be hand sealed. DO NOT
use on vertic
al side walls.
t3&-&"4&'*-.Plastic film strips are present either on the back or face of each shingle. The film strips are to prevent shingles from sticking
together while in the bundle. Do not remove the film strip before or during the application.
t5)306()7&/5*-"5*0/For optimal shingle life and to help prevent mold growth, all roof structures must have through ventilation to prevent
entrapment of moisture-laden air behind roof sheathing. Ventilation must be designed to meet or exceed current F.H.A., H.U.D. or local code
minimum requirements. Note: Minimum net free ventilation area of 1 sq. foot per 150 sq. feet (1 sq. meter per 150 sq. meters) of ceiling area
is required. When vents are located at the eaves and near the roof’s peak (balanced) for maximum air flow, ventilation may be reduced to 1 sq.
foot per 300 sq. feet (1 sq. meter per 300 sq. meters).
t&9104&%.&5"-Paint all exposed metal surfaces (flashing, vents, etc.) with matching GAF Shingle-M
atch
™
roof accessory paint for
best appearance.
tNOTE: All drawings not drawn to scale.
INSTRUCCIONES GENERALES
t1-"5"'03."4#"4&%&5&$)04 Use una plataforma base de 3/8" (10mm) de madera terciada u madera aglomerada orientada (OSB por
sus siglas en inglés) como mínimo según lo recomendado por la Asociación Americana de Madera Terciada (APA por sus siglas en inglés).
Las cubiertas de madera deben estar bien preparadas y apoyadas, con un espacio máximo de 1/8" (3mm), con un espesor mínimo nominal de
1"(25mm), con un ancho máximo de 6" (152mm), y una capacidad de retención de clavos adecuad
a y una superficie suave. NO asegure las tejas
directamente al aislante o a la plataforma base aislada a menos que sea autorizado por escrito por GAF. Las plataformas base de techo y material
de superficie existentes deben estar secas antes de la aplicación de las tejas.
t$"1"#"4&CBSSFSBDPOUSBHPUFSBT Instale barrera de filtraciones de GAF en los aleros en lugares donde el estancamiento de agua detrás de
hielo o desechos podrí
a causar filtraciones.
t$"1"#"4&1305&$$*»/1"3"$6#*&35"4%&5&$)04 La capa base debajo de las tejas tiene muchos beneficios, incluyendo el ayudar a
evitar que la lluvia arrastrada por el viento alcance el interior del edificio y evitar que la savia de algunas plataformas de madera reaccione con
las tejas asfálticas. La capa base también es requerida por muchos códigos de construcción para mantener la
calificación Clase A de UL contra
incendios. Donde vaya a instalar una capa base, use una de tipo respirable como las capas base Shingle-Mate
®
o Deck-Armor
™
de GAF. También
se puede utilizar la capa base Tiger Paw
™
de GAF, con su diseño de control de la humedad. Siempre pida a un profesional en diseño que revise los
requisitos de ventilación cuando utilice una capa base con diseño de control de la humedad.
t46+&5"%03&4 Use únicamente clavos de techado de acero o aluminio galvanizados, de calibre 10-12, arponados, deformados o con espiga
suave con cabezas de 3/8" (10mm) a 7/16" (12mm) de diámetro. Los sujetadores deben ser suficientemente largos como para penetrar al
menos 3/4" (19mm) en las plataformas base de techos o apenas a través de las plata
formas base de madera terciada. Los sujetadores deben ser
clavados a nivel con la superficie de la teja. Clavar en exceso puede dañar la teja. Los clavos sobresalientes interferirán con el sellado de las tejas,
y pueden doblarse hacia atrás.