PACKAGED PRODUCT DATA
THEORETICAL
COVERAGE:
Make sure LiquidRoofTape overlaps all applied areas by at least 2” in all directions at
approximately 1/8” thickness. This provides a coverage rate of 38 LFT/gallon (11.7 LM/gallon)
with a 4” (10.2 cm) wide path. Alternatively, 1 gallon of product will cover approximately 350
fasteners based on 2” (5.1 cm) patches at 1/8” thickness. Coverage rate may vary with the type
of application and texture of the substrate.
SOLIDS:
Weight: Method 4041 80% ± 1%
Fed. Std. 141
Volume: 68% ± 1%
V.O.C:
250 g/L
FLASH POINT:
ASTM D93 103°F (39°C)
STORAGE STABILITY:
Two years from date of manufacture when stored in unopened containers below 75°F (24°C).
APPLICATION
MIXING:
Mix before application to assure uniform color and consistency. Power mixing is recommended
for quantities greater than 1 gallon (3.8 L). Do not use a paint shaker to mix.
PRIMER:
None normally required.
THINNING:
Product should not be thinned.
APPLICATION:
Apply LiquidRoofTape to a clean, dry and sound surface. Apply by brush, roller, trowel or putty
knife as received. Force the product down into all penetrations and over all protrusions. For cold
weather application, keep material stored above 65°F (18°C). Ensure that previous applications
of LiquidRoofTape or GacoRoof are clean, dry and well cured before recoating.
CLEAN UP:
Application tools and equipment can be cleaned with GacoFlex Silicone Solvent or 100% Pure
Mineral Spirits. DO NOT USE WATER OR RECLAIMED SOLVENTS.
DRY TIME:
Allow the first coat to dry for 3 to 12 hours. Apply top coats as soon as the first coat can be
safely walked on.
CAUTION:
For specific Health and Safety information please refer to the Safety Data Sheet.