User's Manual

G7 EXOTECHNICAL USER MANUAL || 11
3.3 BATTERY
All EXOs are shipped with a pre-installed battery pack and a quick charger.
Battery life
The battery pack can power EXO for over 100 days. This will vary
depending on device congurations, alarm and alert response,
operating temperature, sensor types and pump usage. In operational
temperatures below -20°C (-4°F), the battery pack’s runtime will drop
signicantly. See section 8.4 for more information about running EXO in
cold temperature.
Battery storage
For long-term storage, Blackline recommends the battery is stored at
20°C (68°F).
QUICK CHARGER
The EXO quick charger connects directly to the EXO battery and
charges it overnight. Removal of the battery from EXO must be
done in a safe environment with a clean atmosphere, specically an
atmosphere without explosive gas.
SAFETY WARNING: DO NOT allow metal tools or personal items to touch
the battery terminals. Touching metal or any conductive material to the
battery terminals is extremely dangerous and will damage the battery.
SAFETY WARNING: The EXO quick charger is NOT intrinsically safe. It
should only be used in a safe environment with a clean atmosphere.
To remove the battery
1. Power o EXO
2. Ensure EXO is in a safe environment with a clean atmosphere
3. Loosen the two self-retaining screws at the top of the battery on
the back of EXO
NOTE: This requires a 4mm hex key (included with EXO)
4. Pull the top of the battery away from EXO
NOTE: When vertical, the battery will lean away from EXO allowing
you to grip and remove the battery
Quick charge port
Self-retaining
screws, 4mm
Battery gauge
Battery gauge
Press and hold the battery gauge button on the battery pack
to show how much charge the battery has.
NOTE: A dim bar indicates when the batterys charge is in the
lower half of the bar’s persentage range.
Battery gauge while charging
The Battery gauge will automatically light up and remain lit
while the battery pack is charging. The gauge will display
the current charge of the battery pack as described above.
When the battery reaches 100% it will stop charging and the
gauge’s lights will turn o.
5 bars: 85-100%
4 bars: 65-84%
3 bars: 45-64%
2 bars: 25-44%
1 bar: 5-24%
1 bar blinking: 0-4%