User Manual
4
External Reader Connections (Optional)
0V
0/CK
1/DA
+V
Reader
TB1
Magstripe
0V
0/CK
1/DA
+V
Reader
TB1
Wiegand
Wiegand Reader
Magstripe Reader
IN 1
IN 2
C
SPKR
Reader
TB2
I/O Connections
5
General Purpose Inputs & Outputs (Optional)
COM
NC
NO
SPKR
Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession;
there is no need, for example, to wait for "UNLOCKED" to disappear before presenting another.
If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the O
key, entering your card number, then pressing the P key.
A Setup menu can be displayed by pressing the O and P keys simultaneously while power is applied. You
can use the menu to change the contrast and language used for the LCD (default English). Use the four
function keys to navigate around the menu.
9600-0537. Installation and User Instructions for S884 Readers,
Issue x1.0 19th April 2010. G4S Technology, 2010.
FCC Notice: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Any unauthorized modification to this device may void the authority of
the user to operate it. All trademarks acknowledged.
©
LED Status Indicator
GREEN – The lock is released and you may open the door.
RED – You do not have access rights to gain entry, or the reader did not read your card
properly (in this case, present it again).
YELLOW – Enter your PIN. If you make a mistake, the message INVALID PIN is momentarily
displayed, followed by ENTER PIN, to prompt you to try again.
Specifications
Input voltage: 9-14Vdc.
Input current: 200mA @ nom. 12Vdc.
Operating temperature: 14 to 131°F (-10 to 55°C)
Operating humidity: 15 to 90%, non-condensing.
Maximum read range: 4" (100mm).
Approvals: EN50133, EN302291, EN301489
6
Using the Reader
Note: Use LK4 to select the External Reader type (See Step 3).
The reader is connected to the controller using the 20mA current loop scheme shown in section 2 and, in
addition, the external reader is connected as shown below.
0V
Clock
Data
12V
0V
0s
1s
12V