User's Manual
Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession; there is no need, for
example, to wait for "GREEN LED’s" to disappear before presenting another.
If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the O key, entering your
card number, then pressing the P key.
Please refer to M2150 Intrusion Guide, 9600-0540 for IDS Arm / Disarm procedure.
9600-0596. Installation and User Instructions for S874 Keypad
Readers, Issue 1.0x2 12th March 2012. G4S Technology, 2012.
FCC Notice: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
Any unauthorized modification to this device may void the authority of
the user to operate it. All trademarks acknowledged.
©
LED Status Indicator
GREEN – The lock is released and you may open the door.
RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again).
YELLOW – Enter your PIN. If you make a mistake, the RED LED’s are momentarily displayed, followed by YELLOW LED’s,
to prompt you to try again.
Specifications
Input voltage: 9-14Vdc.
Input current: 120mA @ nom. 12Vdc.
Operating temperature: 14 to 131°F (-10 to 55°C)
Operating humidity: 15 to 90%, non-condensing.
Maximum read range: 4" (100mm).
Approvals:EN302291, EN301489
4
Using the Reader
Set SW1 switch2 (COM) to W for Wiegand communications, or C for 20mA current loop communications. Set SW1 switch1
F/B - Keypad audio feedback) to 1 for sound on, or 0 for sound off.
3
Switch Settings