User Manual
0V
RX+
RX-
TX+
TX-
12V
Reader
Controller
20mA current loop
The I/O terminal is for
connection to a RIM
(see the RIM
Instructions).
0V
TX+
TX-
I/0
RX+
RX-
+V
Ground
Data 0
Green
Data 1
12V
Reader
Controller
Wiegand
0V
0
GRN
1
+V
For a contactless card present the card face-on to the reader until you hear a "bleep". For a contact card,
insert the card (chip upwards and facing you) into the slot at the bottom of the reader until you hear a
“bleep”. Cards can be presented in rapid succession; there is no need, for example, to wait for
"UNLOCKED" to disappear before presenting another.
If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the
# key, entering your card number, then pressing the * key.
A Setup menu can be displayed by pressing the * and # keys simultaneously while power is applied. You can
use the menu to change the contrast and language used for the LCD (default English). At the prompts, press
9600-0453. Installation and User Instructions for S854 Readers,
Issue 1.0.2 26th November 2010. G4S Technology, 2009.
FCC Notice: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Any unauthorized modification to this device may void the authority of
the user to operate it. All trademarks acknowledged.
©
About the Reader Messages
}
READY –
UNLOCKED – The lock is released and you may open the door.
ACCESS DENIED & LOCKED – You do not have access rights to gain entry, or the reader
did not read your card properly (in this case, present it again).
ENTER PIN – Enter your PIN. If you make a mistake, the message INCORRECT PIN is
momentarily displayed, followed by ENTER PIN, to prompt you to try again.
CARD PIN AND # – Enter the DESfire card PIN, then press # if the PIN is less than 8 digits.
The reader is waiting for a valid card to be presented.
(Flashing or steady) – These auxiliary indicators can be configured to operate in
conjunction with conditional commands.
Specifications
Input voltage: 10.2-14Vdc.
Input current (excl. heater): 180mA @ nom. 12Vdc.
Operating temperature: -4 to 158 F (-20 to 70 C)
without heater.
Operating humidity: 15 to 90%, non-condensing.
Maximum read range: 3/4" (20mm).
° °
5
Using the Reader
4
Reader Connections
Note: Use LK3 to select
the communications
mode (see step 3).
Connect shield
at controller end
only
Twisted pairs (use
Belden 9503 cable)
Connect shield at
controller end
only.
Use Belden
9537 cable
Slide the ferrite sleeve onto cable before wiring terminal block. Ferrite to be placed 50mm (2") up cable
and held in place with cable ties.
Note: The FERRITE must be fitted!