User's Manual
Specifications
Input voltage: 9-14Vdc.
Input current (excl. heater): 195mA @ nom. 12Vdc.
Operating temperature: -4 to 158 F (-20 to 70 C)
without heater.
Operating humidity: 15 to 90%, non-condensing.
Max. read range (MIFARE DESfire): 1.2" (30mm).
Approvals: EN50133, R&TTE, IP656.
°°
0V
Connect shield at controller
end only (attach to case).
RX+
RX-
TX+
TX-
12V
Reader
Twisted pairs (use
Belden 9503 cable)
Controller
connections
(20mA current
loop)
The I/O terminal is for
connection to a RIM (see
the RIM Instructions).
On completion, re-secure
the reader to the backplate.
0V
TX+
Do not use
TX-
I/0
RX+
RX-
+V
4
Reader Connections
9600-0348. Installation and User Instructions for S853 Readers,
Issue 1.0 5th August 2004. Group 4 Technology, 2004.
All trademarks acknowledged. Philips and
MIFARE are registered trademarks of Philips Electronics N.V.
FCC Notice: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Any unauthorized modification to this device may void the authority of
the user to operate it.
©
For a contactless card, present the card face-on to the reader until you hear "bleep". For a contact card,
insert the card (chip upwards and facing you) into the slot at the bottom of the reader until you hear a
"bleep". Cards can be presented in rapid succession; there is no need, for example, to wait for
UNLOCKED" to efore presenting another." disappear b
If the reader has been enabled for user-code mode at the controller, you can gain access by pressing
the # key, entering your card number, then pressing the * key.
About the Reader Messages
}
READY
UNLOCKED
ACCESS DENIED & LOCKED
ENTER PIN
CARD PIN AND #
–
– The lock is released and you may open the door.
– You do not have access rights to gain entry, or the reader
did not read your card properly (in this case, present it again).
– Enter your PIN. If you make a mistake, the message INCORRECT PIN is
momentarily displayed, followed by ENTER PIN, to prompt you to try again.
– Enter the DESfire card PIN, then press # if the PIN is less than 8 digits.
The reader is waiting for a valid card to be presented.
(Flashing or steady) – These auxiliary indicators can be configured to operate in
conjunction with conditional commands.
6
Using the Reader
The reader supports the first two contactless and the first contact card types/formats presented after
power-up. For example, encoded MIFARE and encoded MIFARE DESfire (in this example, unencoded
cards would not be recognized). The reader enters this configuration mode whenever power is re-applied.
A reader Setup menu can be displayed by pressing the * and # keys simultaneously while power is
applied. You can use the menu to change the contrast and language used for the LCD (default English),
and view/clear the three card types/formats programmed. At the prompts, press * for No and # for Yes.
5
Reader Configuration