User Manual

9600-0304. Installation and User Instructions for S821
Readers, Issue 1.0x8 8th October 2003. AMAG Technology,
2003.
FCC Notice: This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
Any unauthorized modification to this device may void the
authority of the user to operate it.
All trademarks acknowledged. Texas Instruments is a
trademark of Texas Instruments Incorporated. Philips and
MIFARE are registered trademarks of Philips Electronics, NV.
©
Specifications
Input voltage: 9-14V.
Input current: 110mA @ nominal 12Vdc supply.
Operating temperature: -13 to 158 F (-25 to 70 C).
Operating humidity: 15 to 90%, non-condensing.
Maximum read range: 3" (80mm).
Approvals: EN50133, R&TTE, IP656.
°°
4
Using the Reader
Present the card face-on to the reader until you hear a "bleep". If the green indicator is lit, the card
has been accepted and the door is unlocked. If the red indicator is lit, either the card has not been
accepted, or you do not have access through the door. If the read and green indicators flash
alternatively, please wait.
cards can be presented in rapid succession - there is no need to wait for the green or red
LED to extinguish before presenting another card.
Note:
2
Reader Connections
20mA Current Loop Reader Connections
0V
Connect shield at
controller end only
(connect to case)
Tx-
Tx+
Rx-
Rx+
12V
Controller connections
(20mA reader port)
Red
Black
White
Blue
Green
Orange
Note: the brown
wire is not used
Reader
The reader supports the first two different card types/formats presented after power-up. For
example, unencoded MIFARE and encoded TI cards (in this example, unencoded TI cards would
not be recognized). The reader enters this configuration mode whenever power is re-applied.
3
Reader Configuration