Installation and Operating Manual
Page | 5
MECHANICALSPECIFICATIONS:
Size : 6.5 x 15.4 x 8.0 inch
: (165.1 x 391.16 x 203.2 mm)
RF Connectors : N-Type Female
Weight : 32.0 Lbs. (14.5 kg.) approx.
ENVIRONMENTALCONDITIONS:
The unit is designed for indoor applications:
Operating temperature: - 30°C to + 55°C
Storage temperature: - 50°C to + 90°C
FCCNOTE:
The Federal Communications Commission (FCC) has tested this product and found it to
comply with their RF Exposure Requirements, pursuant to FCC Part 27.
ICNOTE:
The Industry Canada (IC) has tested this product and found it to comply with their RF
Exposure Requirements, pursuant to
IC RSS-131.
NOTE:
The Manufacturer’s rated output power of this equipment is for single carrier operation. For
situations when multiple carrier signals are present, the rating would have to be reduced by
3.5 dB, especially where the output signal is re-radiated and can cause interference to
adjacent band users. This power reduction is to be by means of input power or gain reduction
and not by an attenuator at the output of the device.
RFEXPOSUREWARNING‐FCC:
In order to comply with the FCC RF exposure requirements, the BDA-LTE/LABC-33/33-90-AB
antenna installation must comply with the following:
The outdoor antenna (Yagi type or similar directional antenna if off air donor signal used) must
be installed so as to provide a minimum separation distance of 44 cm between the antenna
and persons within the area. (This assumes a typical antenna with gain of [7.5 dBi, VSWR ≤
1.5:1, Zo= 50 ohms).
The indoor antenna (Omni directional) must be installed so as to provide a minimum
separation distance of at least 23 cm between the indoor antenna connected to the RF
booster and the human user’s body within the area. (This assumes a typical wide-beam type
antenna with gain of 0-2 dBi, VSWR ≤ 2:1, Zo= 50 ohms,).