ELECTRICAL SPECIFICATIONS
Frequency Range
380-512 MHz
Bandwidth
1-3 MHz
Minimum pass band separation
1 MHz
Pass band Gain @ Min. attenuation
Up to 80±2 dB
Variable Step Attenuator Range 2-dB
steps
0-30 dB
Maximum Input Signal Level
-30 dBm
Input/Output Impedance
50 Ohms
VSWR (Input/Output)
<1.5: 1
Power Supply
110VAC/1.6Amps
220VAC/0.8Amps
50 to 60 Hz
MECHANICAL SPECIFICATIONS
Size
16.4 x 8 x 15.3 inch
RF
Connectors
N-Type Female
Weight
43.3 Lb. (19.5 kg)
approx.
ENVIRONMENTAL CONDITIONS
The unit is designed for indoor applications:
Operating temperature: - 30°C to +55°C
Storage temperature: - 40°C to +85°C
Composite Output
Power
27 dBm
31 dBm
33 dBm
36 dBm
Gain Flatness [dB]
± 2.0
± 2.0
± 1.5
± 2.0
Noise Figure [dB]
7.0 (Max.)
6.5 (Typ.)
6.0 (Max.)
5.5 (Typ.)
6.0 (Max.)
5.5 (Typ.)
8.0 (Max.)
7.5 (Typ.)
Output Power ALC Set
[dBm]
UL: +27 ±1
DL: +27 ±1
UL: +31 ±1
DL: +31 ±1
UL: +33 ±1
DL: +33 ±1
UL: +36 ±1
DL: +36 ±1
3rd Order Intercept Point
[dBm]
UL: +48
(Typ.)
DL: +48
(Typ.)
UL: +51
(Typ.)
DL: +51
(Typ.)
UL: +54
(Typ.)
DL: +54
(Typ.)
UL: +54
(Typ.)
DL: +54
(Typ.)