G-SPEED Manual
G-SPEED Product Guide 
Pa
g
e 12 
4. Accept all other default settings on the Quick Create 
page. To complete the process and create the RAID/Volume 
Set, check the “Confirm The Operation” check box and hit 
the “Submit” button. This will begin the initialization 
process. 
5. The initialization process can take from a few seconds to 
over 3 hours depending on the RAID level chosen and the 
size of the array. 
Drives  RAID 0  RAID 3 
(6) 250GB Drives  <1min  1h 18m 
(6) 500GB Drives  <1min  2h 49m 
(6) 750GB Drives  <1min  3h 19m 
6. Once the initialization is complete, reboot your computer 
system and the array will appear as a blank disk, ready to 
be formatted. Refer to your system documentation for 
instructions on formatting G-SPEED for your operating 
system.
8.4 Deleting a RAID set 
1. Select “Delete Raid Set” under the “RaidSet Functions” 
on the left navigation bar. The following screen will appear: 
Check the “Confirm The Operation” checkbox and hit the 
“Submit” button. 
WARNING: THIS OPERATION WILL DELETE THE 
RAID SET AND ANY DATA ON THE G-SPEED!! 
The G-SPEED is now ready to be re-configured. See Section 
8.2 for details on configuring a RAID Set on G-SPEED. 
9. HARDWARE MONITORING 
1. Should hardware fail in your G-SPEED the system alerts 
the user in the following ways: 
A. The Status LED will flash: 
B. An audible alarm will sound (audible alarm is enabled 
by default – to disable see Section 10.1) 
Status LED 
Flashing 