Product manual
Conguring G-SPEED Studio XL
G SPEED
STUDIO
XL
with Thunderbolt™
p. 82
Viewing Logical Drive Check Tables
This feature allows you to view error tables. Use this information to evaluate the integrity of a logical
drive and determine whether corrective action is needed.
To view logical drive check tables:
1. Do one of the following actions:
•Clickthe Logical Drive icon.
•FromtheStoragemenu,chooseLogical Drive. The list of logical drives will appear.
2. Mouse-over the logical drive you want, then click the Check Table button.
3. Choose an option:
•All – All errors (default)
•Read Check – Read errors for this logical drive
•Write Check – Write errors for this logical drive
•Inconsistent Block – Inconsistent blocks for this logical drive, meaning that mirror
data for RAID levels 1, 1E and 10 and/or parity data for RAID levels 5 and 6 may contain
errors. Inconsistencies are identified by the Redundancy Check.
The Check Table lists:
•Table Type – Read Check, Write Check or Inconsistent Block
•Start Logical Block Address – The LBA of the first block for this entry
•Count – The number of errors or continuous blocks starting from this LBA
4. Click the X icon to close the information panel.
To clear the check tables, see Clearing Statistics.
Creating a Logical Drive Manually
This feature creates a logical drive only. You can also use the Wizard to create a disk array with logical
drives and spare drives concurrently. See Creating a Disk Array and Logical Drive With the Wizard. To
create a logical drive manually: