User Manual

p. 82
Conguring G-SPEED Studio R
Viewing Logical Drive Check Tables
This feature allows you to view error tables. Use this information to evaluate the integrity
of a logical drive and determine whether corrective action is needed.
To view logical drive check tables:
1. Do one of the following actions:
• Click the Logical Drive icon.
• From the Storage menu, choose Logical Drive. The list of logical drives will
appear.
2. Mouse-over the logical drive you want, then click the Check Table button.
3. Choose an option:
All – All errors (default)
Read Check – Read errors for this logical drive
Write CheckWrite errors for this logical drive
Inconsistent Block – Inconsistent blocks for this logical drive, meaning that mirror
data for RAID levels 1, 1E and 10 and/or parity data for RAID levels 5 and 6 may
contain errors. Inconsistencies are identified by the Redundancy Check.
The Check Table lists:
Table Type – Read Check, Write Check or Inconsistent Block
Start Logical Block AddressThe LBA of the first block for this entry
CountThe number of errors or continuous blocks starting from this LBA
4. Click the X icon to close the information panel.
To clear the check tables, see Clearing Statistics.
Creating a Logical Drive Manually
This feature creates a logical drive only. You can also use the Wizard to create a disk array
with logical drives and spare drives concurrently. See Creating a Disk Array and Logical
Drive With the Wizard. To create a logical drive manually: