Users Manual
Operating Manual Smart Weather Sensor
98 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
%
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
Buffer ‘1’
Wind Direction (vct)
580
0.0
359.9
°
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Precipitation Type
700
0, 60, 70
Precipitation Intensity
840
0.0000
7.8740
in/h
Buffer ‘2’
Dew Point (act)
115
-58.0
140.0
°F
Wind chill Temperature (act)
116
-76.0
158.0
°F
Amount of Precip. difference
645
0.0000
3937.0000
in
Buffer ‘3’
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Wind Quality
805
0.0
100.0
%
Buffer ‘4’
Wind Direction(act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg