Users Manual

Operating Manual Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 37
Figure 12: Pressure
Settings
Figure 13: Wind
Settings
10.2.5 Pressure,
Altitude: Enter the local altitude in meters here for the correct calculation of
relative air pressure (referenced to sea level).
Offset: Absolute offset on the measurement in the unit indicated in the parameter
description field.
Interval: Time in minutes for the minimum, maximum and average value
calculation interval.
10.2.6 Wind and Compass Settings
Compass correction:
With activated compass correction all wind direction values will be
corrected according to the alignment of the sensor, as evaluated by the
compass.
Windspeed min: Minimum wind speed from which a measurement is transmitted, in the
unit unit indicated in the parameter description field
Setpoint Temp.: Setpoint temperature in °C for the wind sensor heating
Interval: Time in minutes for the minimum, maximum and average value
calculation interval.
Heater mode: The device can be configured for heating in different operating modes.
Configure as ‘automatic’ in normal operating mode. You can find a
precise description of the operating modes on page 47.
Heater Temp. Mode 1:
Temperature in °C, below which the heating is active in Mode 1
Eco Mode Follow Up Time:
On-time of the heating in Eco Mode 1
Deviation: Dependent on the location of the installation; the local declination of the
earth magnetic field has to be considered.